f



How can I convert the "AI one pt" symbol from LabVIEW 6.3 to LabVIEW 8.0?

Hi,
 
I've got an assignment with LabVIEW and I work with LabVIEW 8.0. The program I work with is written in LabVIEW 6.3 and had to be converted to LabVIEW 8.0. That went very well, except for one symbol. The "AI one pt" symbol (see enclosed figure) turned into an empty box (question mark). My question to you is how can I overcome this problem, or how can I simulate this symbol with LabVIEW 8.0?
 
With kind regards,
 
Sander Smeets
 
<img src="http://www.ese.upenn.edu/rca/software/Labview/labview41/inputoutput/AISamplechannel.gif">
0
x9561 (148438)
10/4/2007 6:41:02 PM
comp.lang.labview 35210 articles. 1 followers. vasusachin24 (1) is leader. Post Follow

2 Replies
954 Views

Similar Articles

[PageSpeed] 6

Hello,
Graziano is right about this. To make it completly clear: The block you refer to as a symbol is a VI belonging to the Traditional NI-DAQ driver. Currently there are two drivers for DAQ boards: DAQmx (the new one) and Traditional NI-DAQ (the old one). Since your VI was written in LabVIEW 6.x (6.3 never existed) the VI uses the old driver. What you need to do is: install Traditional NI-DAQ on your PC to get the support VI's for the driver in LabVIEW. This Traditional NI-DAQ installer&nbsp;should be on the driver CD which was delivered along with LabVIEW 8.0 or you can download it here:
<a href="http://joule.ni.com/nidu/cds/view/p/id/586/lang/en" target="_blank">http://joule.ni.com/nidu/cds/view/p/id/586/lang/en</a> 
There is one good point though which Graziano already mentioned: Which DAQ board are you using? It could be that you will need an ever older version of NI-DAQ (traditional) to get your DAQ board supported. Let me know if you have any more questions
Regards,
RikP - National Instruments Applications Engineering
0
x9561 (148438)
10/5/2007 7:40:14 AM
Hello,
&nbsp;
I want to thank you for your answers. It helped me very much!
&nbsp;
With kind regards,
&nbsp;
Sander Smeets
0
x9561 (148438)
10/10/2007 9:40:05 AM
Reply:

Similar Artilces:

How can I modify the &quot;Type definitions&quot; of &quot;Function Prototype&quot; if I want build a DLL in Labview 8.5.1.?
Hello,We have a library with several VIs (API - Interfaces to our Real Time Target). This VIs we provide to our customer to generate own VIs to control the Real Time Target.Now we want to provide the functionality of this VI-library as DLL to our customer. The problem is, that labview use self definite name of type definitions. Also if I use "strict Type definition".Example:void GetOutputValues(VARIANT *Scale_In, int32_t ModelNr, uint16_t SignalID[], TD1:smileymad: *errorIn, VARIANT *Scale_Out, TD2 *Data, TD1 *errorOut, int32_t len)It is possible to modify "TD1" and "TD2"? I want to give useful names.GreetingsSteffen Hi Steffen, &nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Try&nbsp;editing the .h file as follows: CHANGE FROM: typedef struct {&nbsp;LVBoolean status;&nbsp;long code;&nbsp;LStrHandle source;&nbsp;} TD1; CHANGE TO: typedef struct {&nbsp;LVBoolean status;&nbsp;long code;&nbsp;LStrHandle source;&nbsp;} TD1; typedef struct {&nbsp;LVBoolean status;&nbsp;long code;&nbsp;LStrHandle source;&nbsp;} LVErrorCluster; then your GetOutputValues prototype becomes: void GetOutputValues(VARIANT *Scale_In, int32_t ModelNr, uint16_t SignalID[], LVErrorCluster *errorIn, VARIANT *Scale_Out, TD2 *Data, LVErrorCluster *errorOut, int32_t len) If your source-code doesn't refer to "TD1", then&nbsp;you probably won't need to keep the TD1 prototype! Cheers. ...

Error 1047 in LabVIEW 8.2: LabVIEW failed to send variable to the script server. Server:&quot;&quot;
I am working with the evaluation version of labVIEW as well and I have run into another error.&nbsp; I am using a MATLAB script node within a for loop and attempting to pass the for loop counter variable into the script.&nbsp; When I run the code it brings up a 1047 error and says "LabVIEW failed to send variable to the script server. Server:"" ".&nbsp; I looked up the error online which seems to have roots in a failed auto initialization of MATLAB.&nbsp; Is there something that I can do in labVIEW to fix the problem or is it strictly a MATLAB error? &nbsp; I really appreciate your help. Hi Patsenat, &nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; We have a knowledgebase document on our system referring to this issue.&nbsp; Try reading through <a href="http://digital.ni.com/public.nsf/allkb/2B3FF46C8512C4F786256CF30071BE53?OpenDocument" target="_blank">this</a> and attempting what it says.&nbsp; If you still have problems, please post again. ...

Adding an &quot;IMAQ Image.ctl&quot; to the &quot;Display State.ctl&quot; of an XControl prevents LabVIEW from creating a probe of &quot;Display State.ctl&quot;
I am working on an extended IMAQ Display control using LabVIEWs XControl capabilities. &nbsp; I need a copy of the original image passed to add some overlays which must not affect the original image. To achieve this I am creating a backup image in the "Init.vi" and deleting it in the "Uninit.vi". I am storing the reference&nbsp;of this image&nbsp;in the "Display State.ctl" which is part of every XControl. &nbsp; As soon as I am adding an "IMAQ Image.ctl" to the Display State cluster, it is no longer possible to generate a probe of the Display State cluster for debugging purposses. I am always getting the message: "Failed to load or create probe." Deleting the "IMAQ Image.ctl" from the cluster makes the probe working again. &nbsp; Is it a bug or am I doing something wrong? &nbsp; I am working with LabVIEW 8.5 and Vision 8.5. &nbsp; Regards &nbsp; Ingo Bartsch Hello Mr. Bartsch, is it possible for you to post a small example to reproduce the behaviour? It would be helpful to get a description in which way you use the typedef files. I found a example/knowledge base where some informations were included to XControl and LV but not with Vision. <a href="http://digital.ni.com/public.nsf/allkb/1DC1ADD2A136DA298625712C00635758?OpenDocument" target="_blank">http://digital.ni.com/public.nsf/allkb/1DC1ADD2A136DA298625712C00635758?OpenDocument</a> Best wishes Ja...

Error Code &quot;1097.....this might corrupted LABVIEW's memory..........&quot; appears after exit the labview and re-start labview
&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;I have a probelm when I use the "tool/import shared library(.dll)" wizard&nbsp;to generate the&nbsp;API from C. &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; The API &nbsp;works correctly when I complete the wizard, but after I exit labview and re-start labview to run&nbsp;the API&nbsp;again. The error 1097 code "......this might corrupted LABVIEW's memory.............."appears. &nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;The only solution now is to re-generate or update the wizard to&nbsp;generate the API. &nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;I try to find the answer in &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; <a href="http://digital.ni.com/public.nsf/allkb/58596F5D41CE8EFB862562AF0074E04C?OpenDocument" target="_blank">http://digital.ni.com/public.nsf/allkb/58596F5D41CE8EFB862562AF0074E04C?OpenDocument</a>&nbsp; &nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; The paragraph in above article shows ........................... &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; "LabVIEW does not crash until it is closedThe most likely problem is that the DLL function being called has corrupted th...

plug-in &quot;not installed&quot; in my LabVIEW project's &quot;Build Specifications&quot;
I moved my LabVIEW project from one computer to another, now when I click on any item under the project's "Build Specifications", I get an error reading "The plug-in for the selected item is not installed on your system." Does anybody know how to fix this? I have no idea what this "plug-in" is.Attached is a screenshot. plug-in error.PNG: http://forums.ni.com/attachments/ni/170/222664/1/plug-in error.PNG ...

&quot;IDDCO ERROR&quot; for Labview 8.0 and Keithley 6487 picoameter
Hi all, I have a 6487 keithley picoameter and I would like to take current mesurements using labview 8.0. What I tried to do is to built a very simple vi with two instrument I/O assistants (one for configuring the picoammeter and another to take measurments as it changes voltage). I have accompliced the same thing in Visual Studio with C#. The problem is that although some times I do get correct measurements there is always one, two or three IDDCO ERROR idications which I do not know what they mean.&nbsp; I can only tell that this does not happen at the same voltage value but it seems rather random. What is wrong? I have attached the vi if anyone is interested. Thanks in advance for any helpAndreas V_bias_test.vi: http://forums.ni.com/attachments/ni/170/324015/1/V_bias_test.vi According to <a href="http://www.keithley.com/search?searchType=general&SearchableText=IDDCO" target="_blank">Keithley</a> , "This error means the instrument received an Illegal Device-dependent Command Option.". I have not used this model Keithley or DDC. One thing you should do is wire the error out of the initialize Instrument Assistant to the for loop to assure that is actually runs before the for loop. ...

labview 8.0 tdm &quot;flush&quot; to force OS to write to disk
Hello, &nbsp; I'm using&nbsp;a producer loop for data acquisition and a consumer loop to write it out to a TDM file.&nbsp;&nbsp;The&nbsp;WindowsXp page file increases from @480MB to @2GB which is no good. &nbsp; I am using LabVIEW 8.0 and do not have the TDMS functions available to me.&nbsp;&nbsp;As I understand it, there is a flush function for the TDMS that forces the OS to write to the disk immediately, thereby freeing&nbsp;the buffer that was holding the data.&nbsp; Is there a way to do this in&nbsp;Labview 8.0? &nbsp; Thanks, Chris&nbsp; Hi Chris, It appears from your post <a href="http://forums.ni.com/ni/board/message?board.id=170&amp;view=by_date_ascending&amp;message.id=317069#M317069" target="_blank">here</a> that you have upgraded to LabVIEW 8.2 and are now using the TDMS VIs.&nbsp; However, I wanted to point out the <a href="http://zone.ni.com/devzone/cda/tut/p/id/6471" target="_blank">G TDMS VIs</a> available for LabVIEW 7.1 and 8.0 in case those might be useful.&nbsp; ...

OpenG &quot;Dynamic Palette&quot; v0.17 released (support for LabVIEW 8.6)
The OpenG Dynamic Palette package allows the OpenG libraries to be seen in the LabVIEW palettes. This release (v0.17) adds support for LabVIEW 8.6. You can download+install this package using <a href="http://jkisoft.com/vipm/" rel="nofollow" target="_blank">VI Package Manager</a> . Just press the "Check the Network for Available Packages" button to refresh your package list. ...

What is the equivalent of the &quot;AI waveform scan.vi&quot; in Labview 8.2 on the Windows Vista platform
Hello, I'm a very newcomer in the Labview area. I'm trying to develop an interface for my lab activities. Now I'm in the way tu switch from Labview 6.1 to Labview 8.2. On the lab computer is installed Windows Vista. The traditional DAQ in not working properly so I installed the DAQmx but neither this is not working properly. My question is what s the equivalent of the "AI waveform scan.vi" in Labview 8.2&nbsp; on the Windows Vista platform? Best wishes to all You first need to check the version of DAQmx that you have installed. The first version with Vista support is 8.5. The latest is <a href="http://joule.ni.com/nidu/cds/view/p/id/965/lang/en" target="_blank">8.7.1</a>. Second, AI Waveform Scan was a fairly high level VI that called multiple DAQ functions. There is no single replacement that I am aware of. You need to use the low level DAQmx functions such as DAQmx Create Channel, DAQmx Timing, DAQmx Start Task, DAQmx Read, etc. If you are converting an old program, you might want to attach that so that someone can look at it and recomend what you need for the conversion. ...

How to interface the Labview and Simulink (Matlab) without using the &quot;NI LabVIEW Simulation Interface Toolkit&quot;?
Hello, I've been using the Labview for the data aquisition. And I also developed a controller in the Simulink (Matlab) environment. I'd like to control my application using both&nbsp;programs. How&nbsp;could I&nbsp;interface the Labview and Simulink (Matlab) without using the "NI LabVIEW Simulation Interface Toolkit"? thank you, Kostya. Hi Kotsya, Thank you for posting to the National Instruments Discussion Forums. If you are not using the Math Interface Toolkit, you may be interested in using the MATLAB� Script Node. This allows you to call MATLAB� commands using ActiveX and I you can call your Simulink model from MATLAB� that way. Here are some resources on how you can do this: <a href="http://zone.ni.com/reference/en-XX/help/371361B-01/gmath/matlab_script_node/" target="_blank">MATLAB � Script Node LabVIEW 8.2 Help</a> <a href="http://digital.ni.com/public.nsf/websearch/4475BC3CEB062C9586256D750058F14B?OpenDocument" target="_blank">How Can I Resolve MATLAB� script node and Xmath Script Node Issues in LabVIEW?</a> Hope this helps! Hi, Abhinav, thank you for your reply. I will try to explore the option with the Script Node. regards, Kostya. &nbsp; &nbsp; ...

Re: VisualBasic &quot;Show &amp; Hide&quot; equivalents in LabView
Hi, I want to show/hide the Labview Help programatically. (Just on the click on single button) How it can be done? Do i have to use event structure on Ctrl + H buttons???:smileyindifferent: Please suggest some solution. Thanks There's a help palette with a primitive called Control Help Window, which should do what you want (assuming you want the context help). <img src="http://forums.ni.com/attachments/ni/170/336539/1/untitled5.PNG"> Message Edited by mathan on 07-01-2008 07:07 AM untitled5.PNG: http://forums.ni.com/attachments/ni/170/336539/1/untitled5.PNG Hi Tst, Thanks. i know that there is a Context Help Window where you can see the help for all the functions or Labview help. i want to show/hide this window programatically. Is it possible? Thanks. Thanks Mathan, This is what i wanted. Thanks. Hi Dev, the first of those functions ("context help window") is what you need - as you can read in the context help window for that function!!!:smileyvery-happy: Yes, i got it. thanks . ...

Labview &quot;Fatal Internal Error &quot;memory.cpp&quot; line 1038
Hi, &nbsp; This is an example file provided by NI and can be found in Labview 8.2\examples\instr\niHSDIO: Dynamic Generation.lib. Inside this library, there is a file called "Dynamic Generation.vi". If I copied "Dynamic Generation.vi" to other place, the labview will crash. Error message: &nbsp; "Fatal Internal Error. "memory.cpp". Line 1038. Labview version 7.1.1. You will lose any unused work, please contact NI, etc, etc" &nbsp; In the mean time, the Windows freeze. Mouse right click no response. No status bar at the bottom of the screen. The whole desktop is blank. All icons on the desktop disappeared. I have to log-off and re-login to re-active everything. &nbsp; I also tried to copy&nbsp;other VI's in other library files. Same thing happened. &nbsp; Thanks, Jing I&nbsp;was using Labview 8.2.1 when I had this crash, though I have Labview 7 installed in the same computer. When I "copy the file to some other place", I mean: Click the *.vi file, ctrl-c and ctrl-v to some other directory. Thanks, Jing ...

LabVIEW 8.5.1 &quot;The build was unsuccessful&quot;
When attempting to build my executable in LabVIEW 8.5.1 I get the following dialog: &nbsp; <img src="http://forums.ni.com/attachments/ni/170/338657/1/Build%20Errors.PNG"> &nbsp; I've tried recreating my build specification, reinstalling LabVIEW, commenting out sections of my code and nothing seems to help.&nbsp; Has anyone encountered this before?&nbsp; Any ideas NI?Message Edited by FlamingYawn on 07-08-2008 11:24 AM Build Errors.PNG: http://forums.ni.com/attachments/ni/170/338657/1/Build Errors.PNG Hi, &nbsp; Are you building a .exe application? In that case, please verify that all your startup and always included VIs exist in the same path and have been properly compiled. You can try Tolls&lt;VI Analyzer&lt; Mass Compile. Also are you using DSC or shared variables in your code? &nbsp; Ipshita C. Hi Ipshita, &nbsp; Thanks for responding.&nbsp; &nbsp; Yes, this is "a .exe application."&nbsp; &nbsp; My startup path is correct, and I tried building with all my "always included" VIs removed.&nbsp; Same error. &nbsp; I've mass compiled several times. &nbsp; I'm not using DSC or shared variables. &nbsp; I'm able to build the executable on another computer with the exact same project and code (we use source code control), so something must be different about my environment or setup. &nbsp; Thanks, &nbsp; Robert I have seen this error before, but ...

can not save nor print &quot;getting started with labview&quot;
From the Evaluation pull- downs, it was impossible to save or print the manual. I had to go into your web site to search the same doc and then save and print that way. Are you asking for some assistance with this? R Hi Adria, &nbsp; The LabVIEW Getting Started Manual can also be found in the LabVIEW Manuals folder under your Start Menu Programs in pdf format. &nbsp; Let me know if there is anything I can help with. ...

&quot;filewatcher labview&quot;
Hallo &nbsp; Hat jemand von Euch bereits einen filewatcher (ein Programm das nachsieht ob ein anderes Programm Daten in ein file schreibt, und mir dann den zugriff auf diese Daten erm�glicht.) Ich ben�tige ein sollches Programm dringend Version 7.1 bis 8.2 vorhanden. &nbsp; Vielen Dank Werner Hallo Thanks for info! To you have a ready program for checking an activity on a file. How could i give a notice for a good answer! Thanks Werner &nbsp; Thanks Gerd nice day ...

Memory is full during &quot;Save As&quot; of LabVIEW 8.5 project
Good Morning All, &nbsp;&nbsp;&nbsp;&nbsp; Have run into a weird issue while trying to rename a LabVIEW 8.5 project. I've got two projects that ended up having the same names (one by me, one by another engineer). I want to open both at the same time, so I figured I'd open the one and do a "save as", or a "rename". The first time it started processing, doing file loads, and then hung looking for a sub-vi, with the search address pointing to the .llb in the LV 8.5 directory where I manually located it. Once that was resolved, and the original project saved I tried again. This time it did a bunch of loading and then gave me an error box with the message:&nbsp; "LabVIEW:&nbsp; Memory is full.&nbsp; Cannot save project 'original project name.lvproj'" This isn't a big project, the machine is a new HP Compaq dual core 2.8GHz with 1.5Gb of ram, so I don't really think that it should be generating anything that big. This happens with either a "save as" or "rename". I ended up just changing the names of the .lvproj .aliases files to the one I needed and it seems to load ok, but it would be nice to understand what is happening here. &nbsp; &nbsp; This is interesting behavior, since NI actually ensured that you would now have the ability to Save As and Rename a project with the <a href="http://www.ni.com/pdf/manuals/371780c.pdf" target="_blank">release ...

&quot;LabVIEW load error code 3&quot; USB drive
Hi Folks, &nbsp;&nbsp;&nbsp;&nbsp;&nbsp; I'm not expecting any solution here, though it would be nice... &nbsp; Twice, recently, I've lost a top-leve VI due to the error below.&nbsp; I suspect the problem is related to working off a new USB drive - a 2G Lexar Firefly.&nbsp; For&nbsp;two or three years a Lexar Jumpdrive Elite (256M) served me flawlessly, after moving to the Firefly ~2 weeks ago, this error&nbsp;has happened twice.&nbsp; BTW,&nbsp;the Firefly is also extremely slow -&nbsp;amazingly&nbsp;slow, considering how much newer it is. &nbsp; If any wiz-kids have dissected the&nbsp;VI binary well enough to, possibly, identify/repair problems, it would be very much appreciated! &nbsp; <img src="http://forums.ni.com/attachments/ni/170/291448/1/LoadErrorCode3.JPG"> &nbsp; Cheers!Message Edited by tbd on 12-19-2007 09:45 PM LoadErrorCode3.JPG: http://forums.ni.com/attachments/ni/170/291448/1/LoadErrorCode3.JPG Hi Phillip, &nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Thanks for the heads-up re:&nbsp;background-apps slowing-down drive.To be honest, I don't know how to find/disable such apps. but now know to look. Re:&nbsp;Lexar Firefly - it's&nbsp;slow by design, though there's no warning on the package when you buy it.&nbsp; Here's the response from their Customer Support: " Jumpdrive Firefly is a non-speed rated Jumpdrive and is made...

OpenG &quot;LabVIEW Data Tools&quot; library v2.8 released
Hello Everyone,There is a new version (2.8) of the OpenG "LabVIEW Data Tools" library (oglib_lvdata package) available. This library contains several routines manipulating LabVIEW data (variants and type descriptors).<img src="http://forums.ni.com/attachments/ni/170/255217/1/lvdata.png"> This release...1) release adds minor performance improvements.See <a href="http://forums.openg.org/index.php?s=&amp;showtopic=281&amp;view=findpost&amp;p=1574" target="_blank">here</a> for more info. You can download+install this package using <a href="http://jkisoft.com/vipm" target="_blank">VI Package Manager</a> . Just press the "Check the Network for Available Packages" button to refresh your package list.Thank you,-Jim KringMessage Edited by Jim Kring on 06-25-2007 10:39 PM lvdata.png: http://forums.ni.com/attachments/ni/170/255217/1/lvdata.png ...

error 7 in &quot;application builder&quot; for LabVIEW 8.5.1
Hello, &nbsp; I am getting an error while building a project for making EXE file. &nbsp; below is the displayed message. &nbsp; Error 7 occurred at Copy in New VILibrary.vi-&gt;AB_Dest_LLB.lvclass:Create_Destination.vi-&gt;AB_Build.lvclassLCreate_Destinations.vi -&gt;AB_Build.lvclasss:Build.vi-&gt;AB_EXE.lvclass:Build.vi-&gt;AB_Engine_BUild.vi-&gt;AB_Build_Invoke.vi-&gt;A B_Build_Invoke.vi.ProxyCaller &nbsp; ============================NI-488: Non-existent GPIB interface. C:\ProgramFile\NationalInstruments \LabVIEW8.5\vi.lib\Utility\libraryn.bin &nbsp; thanks, &nbsp; You can force LabVIEW to recompile the entire VI hierarchy in your project with CTRL+SHIFT+Run Button. Have you imported some old VI's into the project?&nbsp; From a previous version? Did you add files since creating the build parameters?&nbsp; You may want to delete the build parameters and create a new one. RayRMessage Edited by JoeLabView on 07-02-2008 08:35 AM Also, check the path of the reported missing file and make sure it really isn't missing. Thanks George...&nbsp; :) Especially if code moved around (Copy / Paste to another folder / backup, etc..) Thanks Ray and George, I was using VIs of 7.1 version for 8.5 builder. I deleted the previous build parameters and created a new one, it was sucessful. - sriveni &nbsp; Glad it worked.. :) ...

Is &quot;write to digital line.vi&quot; compatible in LabVIEW 7.0
I developed a LabVIEW program to change the logic state of a digital line using the "write to digital line.vi". This was first done in labVIEW 6.1. The version was later upgraded to LabVIEW 7.0 later and the VI doesn't seem to perform the function correctly, meaning when I tried to change the line state from "low" to "high", it doesn't seem to be doing anything. Is this because of compatibility issue of "write to digital line.vi" with LabVIEW 7.0? Thanks! There should be no problem using the traditional DAQ driver in 7.0. After installing 7.0, did you reinstall traditional DAQ? Does the traditional DAQ driver show up in MAX? Do you get any error when you run the VI? Yes, the traditonal NI-DAQ still shows up in MAX under software as well as the Devices and interfaces (because I have traditional NI-DAQ (legacy) devices). Can I have both the traditional NI-DAQ and the NI-DAQmx on my computer? When we first ran it, it did come up with a error message. But after we installed the legacy NI-DAQ (I guessed it is the traditional Ni-DAQ), the error goes away. Could you read anything from it? Thanks a lot! The two can coexist though it has been quite a while since I've had to do it. The thing to make sure is that if the card is supported by both drivers, that the driver you want to use is the active one. You can check and reset it in MAX. ...

Using &quot;To-upper-case&quot; on cluster with Enum (LabVIEW 8.2)
Hi folks, &nbsp;&nbsp;&nbsp;&nbsp; The following example won't compile on my installation of 8.2 ! &nbsp; &nbsp; <img src="http://forums.ni.com/attachments/ni/170/225670/1/ClusterErr.jpg"> &nbsp; Cheers.Message Edited by tbd on 01-23-2007 09:21 PM ClusterErr.jpg: http://forums.ni.com/attachments/ni/170/225670/1/ClusterErr.jpg ClusterErr.vi: http://forums.ni.com/attachments/ni/170/225670/2/ClusterErr.vi It fails the same way under LabVIEW 8.0. Clearly something is not handled properly. (Of course I don't quite see the general&nbsp;usefulness to use "to uppercase" on a simple&nbsp;enum. ;)) altenbach wrote: (Of course I don't quite see the general&nbsp;usefulness to use "to uppercase" on a simple&nbsp;enum. ;)) (tbd momentarily ponders: "Why does it seem there's always something Altenbach doesn't quite see?") &nbsp; Oh, gee,&nbsp;do it (enum to upper-case) all the time&nbsp;when I forget and type enumerated-case-values in all upper-case. :smileywink: &nbsp; &nbsp; <img src="http://forums.ni.com/attachments/ni/170/225670/1/ClusterErr.jpg"> &nbsp; Indeed it doesn't compile.&nbsp; But the To Upper Case VI handles numbers as ASCII codes.&nbsp; How would converting an enum value of 97 to 65 be useful to you?&nbsp; Are you trying to capitalize the strings in the enum's typedef?&nbsp; A case structur...

Labview 8.20
Hi, &nbsp; I have multiple loops/parallel&nbsp;tasks&nbsp;with&nbsp;various communication buses in an RT system which need to write data to its own individual&nbsp;log file which is using an Binary format. What kind of benefits will I get in terms of performance by using the TDM Streaming?&nbsp; The only benefit I foresee is the consolidation of data into an XML type structure and store data into an universal file versus 4 individual ones.:smileysurprised: &nbsp; Are TDMS being handled differently in RT for disk IO&nbsp;management? because each write will take upto 8-9 ms.The goal is to reduce disk IO and improve performance.:smileyindifferent: &nbsp; Any advice? &nbsp; Ashm01Message Edited by ashm01 on 10-30-2006 11:46 PM Hey Bill, Is your application in RT? I would appreciate if you have some benchmarks on this. I am about to convert the binaries to TDMS and was wondering if anyone had any favorable performance gains. Thanks, Ashm01 Hi Ashm01, &nbsp; The TDMS API was developed to facilitate streaming data to disk at high rates, while maintaing the same descriptive information you would find in a TDM file. You might find the following information interesting from an article on Developer Zone (<a href="http://zone.ni.com/devzone/cda/tut/p/id/3539" target="_blank">Introduction to LabVIEW TDM Streaming VIs</a>): &nbsp; Unlike the TDM files, which have a strictly required XML-based header file, T...

LabVIEW RT 8.5.1 &quot;reboot due to system error&quot;
I'm running my app on a quad core RT desktop target.&nbsp; The executable runs anywhere from a few minutes to a few hours before the machine reboots.&nbsp; About half the time I get the "reboot due to system error" and the "software state: safe mode" messages.&nbsp; rtlog.txt has no record of the reboot. &nbsp; Is there any way to get LabVIEW to log any useful data when this happens? &nbsp; What actions can I take to track this down (other than disabling portions of my code to see what part might be causing it)? Connect up a display to&nbsp; the RT chassi to see if you get any message there. In addition, watch your memory useage. If you run out of memory,&nbsp;RT will just STB. :smileysurprised: Ben Hey Ben, Thanks for responding. I do have a display hooked up to my RT desktop, but when it reboots, it reboots.&nbsp; Screen goes blank.&nbsp; No messages. How do you watch the memory usage on the RT target? What does STB mean? Thanks, In LV 8 and up I believe there is a property under the RT target inside the project. STB = "Sh#$ The Bed" Ben You can go to Tools --&gt; Real-Time Module --&gt; System Manager ...

Labview 8.5 error on save: &quot;Cannot load help information of [filename].&quot;
Hi all, &nbsp; &nbsp;I was working on a VI in Labview 8.5 when the program (Labview) crashed. When I relaunched Labview it asked me if I wanted to recover the VI&nbsp;I was working on,&nbsp;I said yes and the recovered VI runs fine, but I cannot save it. When&nbsp;I try to Save or Save As I receive the following error message: "Cannot load help information of [Filename]" and my only option is "Cancel Save". If I click "Cancel Save" Labview returns a "File not Found error". Until the recovery, I could and did save the file with no problems. It now seems that I am locked out of the file. &nbsp; &nbsp; I have a backup, but it is does not contain the 2-3 hours of work I put in before the crash. Does anyone have a work-around, or know the source of this error? This is the second time I have seen it on a recovered file (the first time I had a fresh backup, so it wasn't a big issue). &nbsp; Here is a dump of the "Referencing files in the project or its dependencies" from the Save As dialog: &nbsp; [Project Name].lvprojreplay2-offsets.vi:Instance:6replay2-offsets.vi:Instance:5replay2-offsets.vi:Instance:3replay2-offsets.vi:Instance:2replay2-offsets.vi:Instance:4replay2-offsets.vi:Instance:1replay2-offsets.vi:Instance:0 &nbsp; Thank you, Tim I'm having the same problem. I came here to see if there was any information about this problem, and found the previous message. Lucky for me, I&#...

Web resources about - How can I convert the &quot;AI one pt&quot; symbol from LabVIEW 6.3 to LabVIEW 8.0? - comp.lang.labview