How can I modify the "Type definitions" of "Function Prototype" if I want build a DLL in Labview 8.5.1.?

Hello,We have a library with several VIs (API - Interfaces to our Real Time Target). This VIs we provide to our customer to generate own VIs to control the Real Time Target.Now we want to provide the functionality of this VI-library as DLL to our customer. The problem is, that labview use self definite name of type definitions. Also if I use "strict Type definition".Example:void GetOutputValues(VARIANT *Scale_In, int32_t ModelNr, uint16_t SignalID[], TD1:smileymad: *errorIn, VARIANT *Scale_Out, TD2 *Data, TD1 *errorOut, int32_t len)It is possible to modify "TD1" and "TD2"? I want to give useful names.GreetingsSteffen
0
x9561 (148441)
4/29/2008 3:10:08 PM
comp.lang.labview 35213 articles. 1 followers. vasusachin24 (1) is leader. Post Follow

1 Replies
831 Views

Similar Articles

[PageSpeed] 45

Hi Steffen,
      Try editing the .h file as follows:
CHANGE FROM:
typedef struct { LVBoolean status; long code; LStrHandle source; } TD1;
CHANGE TO:
typedef struct { LVBoolean status; long code; LStrHandle source; } TD1;
typedef struct { LVBoolean status; long code; LStrHandle source; } LVErrorCluster;
then your GetOutputValues prototype becomes:
void GetOutputValues(VARIANT *Scale_In, int32_t ModelNr, uint16_t SignalID[], LVErrorCluster *errorIn, VARIANT *Scale_Out, TD2 *Data, LVErrorCluster *errorOut, int32_t len)
If your source-code doesn't refer to "TD1", then you probably won't need to keep the TD1 prototype!
Cheers.
0
x9561 (148441)
5/5/2008 12:10:05 AM
Reply:

Similar Artilces:

plug-in "not installed" in my LabVIEW project's "Build Specifications"
I moved my LabVIEW project from one computer to another, now when I click on any item under the project's "Build Specifications", I get an error reading "The plug-in for the selected item is not installed on your system." Does anybody know how to fix this? I have no idea what this "plug-in" is.Attached is a screenshot. plug-in error.PNG: http://forums.ni.com/attachments/ni/170/222664/1/plug-in error.PNG ...

Adding an "IMAQ Image.ctl" to the "Display State.ctl" of an XControl prevents LabVIEW from creating a probe of "Display State.ctl"
I am working on an extended IMAQ Display control using LabVIEWs XControl capabilities. &nbsp; I need a copy of the original image passed to add some overlays which must not affect the original image. To achieve this I am creating a backup image in the "Init.vi" and deleting it in the "Uninit.vi". I am storing the reference&nbsp;of this image&nbsp;in the "Display State.ctl" which is part of every XControl. &nbsp; As soon as I am adding an "IMAQ Image.ctl" to the Display State cluster, it is no longer possible to generate a probe of the Display State cluster for debugging purposses. I am always getting the message: "Failed to load or create probe." Deleting the "IMAQ Image.ctl" from the cluster makes the probe working again. &nbsp; Is it a bug or am I doing something wrong? &nbsp; I am working with LabVIEW 8.5 and Vision 8.5. &nbsp; Regards &nbsp; Ingo Bartsch Hello Mr. Bartsch, is it possible for you to post a small example to reproduce the behaviour? It would be helpful to get a description in which way you use the typedef files. I found a example/knowledge base where some informations were included to XControl and LV but not with Vision. <a href="http://digital.ni.com/public.nsf/allkb/1DC1ADD2A136DA298625712C00635758?OpenDocument" target="_blank">http://digital.ni.com/public.nsf/allkb/1DC1ADD2A136DA298625712C00635758?OpenDocument</a> Best wishes Ja...

How to use &quot;GetLastInputInfo&quot; in &quot;user32.dll&quot;
&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Hi, &nbsp; I need to logout user if he doesn't make action during 5 minutes, "GetLastInputInfo" method in the "user32.dll" library, return the tick of the last action, so I can&nbsp;know the inactivity time of the login user. &nbsp; But I try to using "Call Dll function" item in Labview 8.1, and each time I run VI, Labview crash. &nbsp; Next, is information about the method : &nbsp; DLL###############################User32.dll &nbsp; Syntax###############################BOOL GetLastInputInfo(PLASTINPUTINFO plii); &nbsp; Parameters###############################plii : [out] Pointer to a LASTINPUTINFO structure that receives the time of the last input event. Private Type LASTINPUTINFO &nbsp;&nbsp;&nbsp; cbSize As Long &nbsp;&nbsp;&nbsp; dwTime As Long End Type Return Value###############################If the function succeeds, the return value is nonzero.If the function fails, the return value is zero. &nbsp; Remarks###############################This function is useful for input idle detection. However, GetLastInputInfo does not provide system-wide user input information across all running sessions. Rather, GetLastInputInfo provides session-specific user input information for only the session that invoked the function. &nbsp; You can see also my VI source. &nbsp; GetLastInputInfo.vi: http://forums.ni.com/attachments/ni/170/31...

LabVIEW 8.5.1 &quot;The build was unsuccessful&quot;
When attempting to build my executable in LabVIEW 8.5.1 I get the following dialog: &nbsp; <img src="http://forums.ni.com/attachments/ni/170/338657/1/Build%20Errors.PNG"> &nbsp; I've tried recreating my build specification, reinstalling LabVIEW, commenting out sections of my code and nothing seems to help.&nbsp; Has anyone encountered this before?&nbsp; Any ideas NI?Message Edited by FlamingYawn on 07-08-2008 11:24 AM Build Errors.PNG: http://forums.ni.com/attachments/ni/170/338657/1/Build Errors.PNG Hi, &nbsp; Are you building a .exe application? In that case, please verify that all your startup and always included VIs exist in the same path and have been properly compiled. You can try Tolls&lt;VI Analyzer&lt; Mass Compile. Also are you using DSC or shared variables in your code? &nbsp; Ipshita C. Hi Ipshita, &nbsp; Thanks for responding.&nbsp; &nbsp; Yes, this is "a .exe application."&nbsp; &nbsp; My startup path is correct, and I tried building with all my "always included" VIs removed.&nbsp; Same error. &nbsp; I've mass compiled several times. &nbsp; I'm not using DSC or shared variables. &nbsp; I'm able to build the executable on another computer with the exact same project and code (we use source code control), so something must be different about my environment or setup. &nbsp; Thanks, &nbsp; Robert I have seen this error before, but ...

&quot;re-entrant&quot; &quot;file I/O&quot; &quot;QSM_State Machines&quot;
&nbsp; &nbsp; I have trouble with writing (appending) to text file in a QSM that is in an "occurence mode" of operation whereby the queue waits for outside engueue to go ahead and do a task. The task is simply to write to a file a line of text. &nbsp; Outside producers give the queue its go ahead and data is sent along etc... &nbsp; WHat I am seeing in the logging functions are multiple errors (Error 1) Somehow Labview&nbsp;is not noticing that the reference is valid or it is invalidating the reference. &nbsp; Q is Should I just let the QSM loop to keep it alive and would that work? &nbsp; What is the rule concerning queue waiting for an event? Does the VI get flagged as idle and is that why the ref appears to be dropped?&nbsp; THere is no reason I can think of for the ref to be dropped. It is opened in the init frame then kept in a shift register. and available at each iteration in the QSM. &nbsp; The example works in a simple loop but not a loop that is waiting on an occurence.&nbsp; Why? &nbsp; The only work around I can manage is to use the path and open the reference when it is not valid which feels kind of&nbsp; silly if you get my drift &nbsp; Anyone seen this before? &nbsp; Thank You &nbsp; &nbsp; &nbsp; ...

VI &quot;FindInstrumentDrivers.vi&quot; was stopped at node &quot;&quot; at a call to &quot;IDF_WsIdOpen.vi&quot;
This what I get trying to download Instrument Drivers in LabVIEW 8.2. LabVIEW 8.6 doesn't succeed either. any ideas? Could just be an intermittent server problem. Does this happen all the time? At what point does it fail? When you first launch it, after you login? The network traffic indicates that it uses port 3339. Is this being blocked by your firewall? ...

Programmatic &quot;undo&quot; for &quot;FitControlToPane&quot; ?
Howdy neighbors!, (using LV8.2)&nbsp; I'm trying to develop a GUI that lets the user toggle a Tab-control between "Full Pane" and a&nbsp;reduced size/position - sorta-like&nbsp;the "Full Screen" option on many Video apps.&nbsp; The effect of the&nbsp;invoke-node method "FitControlToPane" is perfect (- :smileyhappy: -), but how to undo that effect?&nbsp; After&nbsp;FitControlToPane,&nbsp;"Scale Object with Pane" is selected in the IDE, yet I can't find a "property" for it. :smileysad:&nbsp; FitControlToPane also changes the visibility of vertical and horizontal scroll-bars - are these [VI Properties] programmatically settable? &nbsp; Cheers! &nbsp; &nbsp; &nbsp; follow up... FitControlToPane also changes the visibility of vertical and horizontal scroll-bars - are these [VI Properties] programmatically settable? Feel kinda silly now, having advised someone else to search LabVIEW's HELP first! :smileytongue: &nbsp;- found Scrollbar Visibility can be set via (LV8.2)\ VI \Panel(reference)\Panes[0].HorizScrollbarVisibility. <img src="http://forums.ni.com/attachments/ni/170/239318/1/ScrollBar.JPG"> Still hunting for an&nbsp;elusive "Set Scaling Mode" method... (The&nbsp;Tab Control's&nbsp;"AutoGrow?" property doesn't seem to do anything!?)Message Edited by tbd on 04-03-2007 12:56 AM ScrollBar.JPG: ht...

How to change &quot;ASRL2:... &quot; to &quot;COM1&quot;?
Dear All, &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; I have used com port in my vi. And When I run it in edit mode,&nbsp;the selection of com displays "COM1,COM2,LTP1". &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; But when I build it, and run it in another PC, it displays "ASRL2:...". &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; How can I modify my vi to make it display COM1... in another PC? &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; And If I only want to display all serial port such as COM1,...

How to define &quot;byte stream type&quot; for &quot;open file&quot;?
Hello, I created some numbers (type "double") in Matlab and stored in a file. What value should I use to specify the "byte stream type" for "open file" in Labview? Should I put something like "DBL" or "I32". I don't know where to find the list of legal "types" in Labiew help. Thanks so much! Felicia Looks like 7.1:<img src="http://forums.ni.com/attachments/ni/170/347924/1/read%20file%207.png"> The Matlab "double" is 64 bits (8 bytes). It doesn't make much sense to use an integer datatype to read a floating point value, so you would use DBL in LabVIEW. The numeric data types table can be found <a href="http://zone.ni.com/reference/en-XX/help/lv/71/lvhelp/Numeric_Data_Types_Table/" target="_blank">here</a>. By the way, this assumes you saved the file as raw binary, as opposed to a .mat file, which is something different. Message Edited by smercurio_fc on 08-08-2008 11:21 AM read file 7.png: http://forums.ni.com/attachments/ni/170/347924/1/read file 7.png Thank both of you! I'm using Labview 6.1 base "Read File", just like the picture above. I've specified the byte stream type as DBL; however, the output is an array of string. What should I do with the string? I've tried to use "Decimal String To Number" but I got an output of "0". I've also tried the "Read From SGL File" in Labivew and ...

'&&&&a'="&&&&a."
I need a data step that is equivalent to data _NULL_; file print; put '&&&&&&a=' "&&&&&&a"; run; Yet the number of & is a variable, I need to write a Macro, so far I got only half of the code('&&&&&&a.='), I don't know how to put the other half ("&&&&&&a.") into Macro Thanks. %Macro R(k); data _NULL_; file print; put %do i= 1 %to &k.; '&' %end; 'a=' ; run; %mend; %R(10); ==================================================...

&quot;VI was stopped at node &quot; &quot; at a call to &quot;In Port Old 6.x.vi&quot;&quot;
Hi. I am having problems with&nbsp;a VI&nbsp;that was initially developed for LABView 6i. I have upgraded to LABView 8.2 but whenever I run the program in LABView 8.2 I get the error message that my VI was stopped at node&nbsp; " " at a call to "In Port Old 6.x.vi". The VI generally aquires data from a measurement instrument via an RS232 COM port. I have searched the forum and the only reference to this problem mentioned that it can be solved by making "minor modifications" to the polymorphic In Port VI in LABView 8.2 but I have no idea how to do this. &nbsp; I would be most grateful if anyone can help me to do this. I am a newbie to LABView programming so I would require as much detail as possible. Thanks. &nbsp; tronix Hello, &nbsp; Have you followed the guidelines found on this document? &nbsp; <a href="http://digital.ni.com/public.nsf/allkb/39129B46944215B686257069006CEC4E?OpenDocument" target="_blank">http://digital.ni.com/public.nsf/allkb/39129B46944215B686257069006CEC4E?OpenDocument</a> &nbsp; Contains information on how to proceed and how you can change the VI's needed to new ones. &nbsp; Hopes this helps! Hello. Thanks for your response. I did see the link. Part of the document says: tronix wrote: Hi. I am having problems with&nbsp;a VI&nbsp;that was initially developed for LABView 6i. I have upgraded to LABView 8.2 but whenever I run the program in L...

how to connect &quot;IMAQ Get Buffer.vi&quot; output terminal of &quot;Image Out&quot; to the input terminal of &quot;Image&quot; of &quot;IMAQ ColorImageToArray.vi&quot;
Hi, Thanks a lot for helping me till this stage.I am again stuck up with some problem.Please help me this time also. Actually i am making changes in already existingblock diagram and also i am new to this labview programming.And also time is very crucial. So i want to know if there is any way to connect the output of Image out terminal of IMAQ Get Buffer.vi to the input terminal of Image of IMAQ ColorImageToArray.vi. In the actual block diagram the output of Image out terminal of IMAQ GetBuffer.vi is connected to the input terminal of Image of IMAQ ImageToArray.vi. I want to change this becos i want to take RGB image as input and seperate R, G, B components. Please explain in terms of bloack diagram. ...

Problems with "&amp;" changing to "&"
A lot of Firefox users I know, says they have problems with validation where the ampersand sign has to be written as &amp; to be valid. I don't have Firefox my self and don't wont to install it only because of this, so I hope some of you gurus can enlighten me with this :) In what circumstances can the "&amp;" in the source code be involuntary changed to "&" by a browser when or other software, when editing and uploading the file to the web server? E.g. writing a string like "sc_project=402887&amp;java=0&amp;security" is cha...

why it keeps on asking &quot;NI LabVIEW 8.5.1&quot; distribution when building installer?
Hi, I am building an installer for one image processing application. For addtional installers, NI Labview runtime engine 8.5.1NI vision runtime engine 8.5NI IMAQdx 3.1.2NI VISA runtime 4.3When building, it keeps on asking "NI LabVIEW 8.5.1" distribution even though I put the CD into CD room, saying it needs to copy a component installed or updated by the distribution to continue building the installer.If&nbsp; NI-IMAQ dx 3.1.2 not checked, it is OK. BUT, I need it.Thanks a lot for any help.Anne Zuo What is a "CD room"? or CD driver. sorry for my language.&nbsp; Take a look at this <a href="http://forums.ni.com/ni/board/message?board.id=170&amp;view=by_date_ascending&amp;message.id=210032#M210032" target="_blank">link</a> and see if it helps. &nbsp; Also, if it doesn't like disk 1, put in disk 2 instead, if not disk 2, then try disk 3.&nbsp; Perhaps it is looking for the driver it needs, but the actual files it is looking for is on the 2nd or 3rd CD. &nbsp; Ultimately, it may be best to copy all of the CD's to your hard drive and have it point to them there. ...

How can I use an iteration value from a &quot;while&quot; (or &quot;for&quot;) loop as part of a filename?
I am using the "Write To Measurement File" function&nbsp; inside a while structure and would like to incorporate the iterative value from the while-loop as part of the file name. I'm not sure how to do it. Any suggestions? &nbsp; ...

How to remove the &quot;int len&quot; of my return string on the DLLS header when building a DLL on LabVIEW 8.5
Hi all. I'm building a DLL on LabVIEW and I choose a string as an output on the terminals connectors. But LabVIEW creates another output, the lenght of the return string. This is a problem because I have other DLLs and&nbsp;I need them to be compatible. How do I remove this length from the header? What is the difference between Pascal String and C string and String Handle Pointer? String Handle Pointer removes the length from the header but I don't know the difference between this data types. Thanks in advance for the help. &nbsp; Daniel Coelho Portugal &nbsp; Daniel Coelho wrote:Hi all. I'm building a DLL on LabVIEW and I choose a string as an output on the terminals connectors. But LabVIEW creates another output, the lenght of the return string. This is a problem because I have other DLLs and&nbsp;I need them to be compatible. How do I remove this length from the header? What is the difference between Pascal String and C string and String Handle Pointer? String Handle Pointer removes the length from the header but I don't know the difference between this data types. Thanks in advance for the help. &nbsp; Daniel Coelho Portugal &nbsp;C string pointer is a pointer to a memory location whose string information is terminated by a 0 byte. Pascal String Pointer is a pointer to a memory location where the first byte specifies the number of bytes to follow. This obviously allows only for strings up to 255 character length.LabVIEW String Hand...

Can classes &quot;make&quot; controls and indicators &quot;appear&quot; on the front panel.
This is what I was hoping to do. I would define a parent class called signal that was really just an interface class. All of the child classes, analog in, analog out, digital in, etc. would have to override the VI?s in the signal class. So, the first thing that the program would do is to read a text file line by line, and on each line there would be a tag telling the program which type of signal to create. Next the newly created signal would be casted up to the parent class and put into an array. Once I have my array of signals, on the front panel I would have an array of text boxes. The text boxes would be displaying the names of the signals. In a search text box, the user can type some of the characters that are in the name of a signal, and the array would reduce the list until the user finds the signal they want. Here?s what I can?t figure out. I wanted the user to click a button next to the text box, that is listing the name of the signal they wanted, and the controls for that type of signal would appear to the right of the text box. How do I make the controls appear to the right of the text box? The controls are basically an indicator for reading an analog input or several controls that allow for ramping or stepping an analog output or setting a digital output or reading a digital input, etc. I?m hoping that the class can ?make? the controls and indicators ?appear? on the front panel. Any suggestions? &nbsp; Thank you! &nbsp; "Then write some helper meth...

The .NET assembly expected to be at &quot;&quot; was loaded from &quot;NULL&quot;
Hello, &nbsp; I use NET Components in a LabVIEW 8.2.1. VI and all work very fine. Now I convert it to LabVIEW 8.5 and I always get a warning, when open it. The Warning is : &nbsp;The .NET assembly expected to be at "" was loaded from "NULL". As example I add my CallbackVI in the Attachment. If somebody has an idea to remove this warning I would be thankful. &nbsp; Thanks in advance TE_NET_ToolStrip.ClickCallback.vi: http://forums.ni.com/attachments/ni/170/304243/1/TE_NET_ToolStrip.ClickCallback.vi Oh I was glad to early. The problem was only solved one time. When I changed something and saved again, I had again the troubles. &nbsp; I will recreate the VIs now. I already done, but it didn't helped. Now I read, that old one should be closed. ...

Difference between &quot;FP Close&quot; and &quot;FP Hidden&quot;
What is the difference between "Front Panel Close" and "Front Panel Hidden" ? "FP Close" works similar to "FP Hidden" at programming mode but not at the executable ! Is this normal ? At the executable "FP Close" seems to terminate the current vi. One more question: "FP Close" prevents the code that follows from been executed. It is a "violent" way to stop your current vi, but not the whole application. Am i right ? To add one additional thing: I made some tests now on how the Close/Hide differs for SubVIs, and saw no difference. So regardless of hiding or closing the FP of a SubVI, the execution of the VI keeps going on until either the VI is stopped or the MainVI gets unloaded.Attached you can find my test: Sub.VI is the Vi called by closeFP.VI using VI-Server. You can toggle several functions of the Sub, but please note that Sub does not get unloaded until closeFP is stopped.Norbert closeFP.vi: http://forums.ni.com/attachments/ni/170/299668/1/closeFP.vi sub.vi: http://forums.ni.com/attachments/ni/170/299668/2/sub.vi ...

The use of the &quot;XY graph&quot; with the &quot;Read Traces&quot;
Hi, I'm trying to plot on "XY Graph"&nbsp; some informations wich are taken directly from the "Read Traces", and the problem is that the Start timestamp wich i enter to the "Read Traces" don't correspond to the beginning of the X axeof the graph. Can some one help me please. Question pour le forum NI.doc: http://forums.ni.com/attachments/ni/170/334716/1/Question pour le forum NI.doc Hi basile Have you found an issue about your problem? Could you attach you code(.vi) please? Thanks. Regards. Hi&nbsp;&nbsp; R_DUVALThank you for your help but I found the solution to my problem.Best Regards ...

Installer &quot;Source file settings&quot;, &quot;VI Settings&quot; problem in 8.2
I have just upgraded from LabVIEW 8.0 to 8.2 and it seems the Installer "Source file settings", "VI Settings" check boxes no longer have any affect on the built application. &nbsp; For example, if I un-check the "Show Menu Bar" boxes for my Main.vi and build, when I run the built application the Main.vi Menu Bar is visible. &nbsp; It seemed to work as expected with 8.0 though. &nbsp; Any help and suggestions are much appreciated. &nbsp; Aaron Hi Seamus, Thanks for that and I look forward to hearing from you again Aaron ...

error 7 in &quot;application builder&quot; for LabVIEW 8.5.1
Hello, &nbsp; I am getting an error while building a project for making EXE file. &nbsp; below is the displayed message. &nbsp; Error 7 occurred at Copy in New VILibrary.vi-&gt;AB_Dest_LLB.lvclass:Create_Destination.vi-&gt;AB_Build.lvclassLCreate_Destinations.vi -&gt;AB_Build.lvclasss:Build.vi-&gt;AB_EXE.lvclass:Build.vi-&gt;AB_Engine_BUild.vi-&gt;AB_Build_Invoke.vi-&gt;A B_Build_Invoke.vi.ProxyCaller &nbsp; ============================NI-488: Non-existent GPIB interface. C:\ProgramFile\NationalInstruments \LabVIEW8.5\vi.lib\Utility\libraryn.bin &nbsp; thanks, &nbsp; You can force LabVIEW to recompile the entire VI hierarchy in your project with CTRL+SHIFT+Run Button. Have you imported some old VI's into the project?&nbsp; From a previous version? Did you add files since creating the build parameters?&nbsp; You may want to delete the build parameters and create a new one. RayRMessage Edited by JoeLabView on 07-02-2008 08:35 AM Also, check the path of the reported missing file and make sure it really isn't missing. Thanks George...&nbsp; :) Especially if code moved around (Copy / Paste to another folder / backup, etc..) Thanks Ray and George, I was using VIs of 7.1 version for 8.5 builder. I deleted the previous build parameters and created a new one, it was sucessful. - sriveni &nbsp; Glad it worked.. :) ...

Race Condition: &quot;Elapsed Time&quot; and &quot;Boolean Crossing&quot;
Hello. We are experiencing a pretty strange issue here and we are not sure how to solve it. The attached VI's are a simplified version of the code, but that exhibits the same behavior: The MAIN vi controls a boolean that is an input of the SUB vi. The SUB vi analyzes this boolean, and if its state is different than the last one read, a timer is reset. While the required time (2 sec) has NOT elapsed, the SUB vi outputs the last remembered value after the time has elapsed, the SUB vi finally outputs the new value. Now, the problem appears when depending on how we change the input boolean (for instance, if you change its state as soon as the "elapsed time pulse" is generated), the new value is NEVER sent to the SUB vi's output. In other words, depending on the moment the input is changed, the SUB vi doesn't get the change and never resets the timer. How can we solve this issue? Is there any special configuration that needs to be done in the used functions? Thank you very much for all help. Daniel ...

Unconfigured, Bad Status &quot;A&quot;, Bad Status &quot;B&quot;
Greeting All. I recently upgraded to LabVIEW 8.5.1, including LabVIEW-RT.My application acquires data from an AI-110 -- Compact FP module.Anyhow, to make a long story short, my program started to malfunction.[After lots of pain and suffering,] I learned that the call fo FP Read produces the error:Unconfigured, Bad Status "A", Bad Status "B"The error is frequent, and I cannot help to think that it is considerably diminishing the performance of all other tasks.Any Ideas? Can you post your code?&nbsp; RayR&nbsp; Certainly. Attached, you'll find a VI that resembles my worker-VI - which I use in my project.I run this VI inside of a state machine.&nbsp; It is initialized at the onset of execution.Thereafter, it is called upon [to read data] at 2Hz.The session is closed at the end.Thanks. ai110.vi: http://forums.ni.com/attachments/ni/170/328071/1/ai110.vi ...

Web resources about - How can I modify the &quot;Type definitions&quot; of &quot;Function Prototype&quot; if I want build a DLL in Labview 8.5.1.? - comp.lang.labview