f



LabVIEW RT 8.5.1 "reboot due to system error"

I'm running my app on a quad core RT desktop target.  The executable runs anywhere from a few minutes to a few hours before the machine reboots.  About half the time I get the "reboot due to system error" and the "software state: safe mode" messages.  rtlog.txt has no record of the reboot.
 
Is there any way to get LabVIEW to log any useful data when this happens?
 
What actions can I take to track this down (other than disabling portions of my code to see what part might be causing it)?
0
x9561 (148440)
6/19/2008 5:40:06 PM
comp.lang.labview 35213 articles. 1 followers. vasusachin24 (1) is leader. Post Follow

4 Replies
926 Views

Similar Articles

[PageSpeed] 42

Connect up a display to  the RT chassi to see if you get any message there.
In addition, watch your memory useage. If you run out of memory, RT will just STB. :smileysurprised:
Ben
0
x9561 (148440)
6/19/2008 5:40:08 PM
Hey Ben,
Thanks for responding.
I do have a display hooked up to my RT desktop, but when it reboots, it reboots.  Screen goes blank.  No messages.
How do you watch the memory usage on the RT target?
What does STB mean?
Thanks,
0
x9561 (148440)
6/19/2008 6:10:05 PM
In LV 8 and up I believe there is a property under the RT target inside the project.
STB = "Sh#$ The Bed"
Ben
0
x9561 (148440)
6/19/2008 6:40:11 PM
You can go to Tools --> Real-Time Module --> System Manager
0
x9561 (148440)
6/19/2008 7:10:06 PM
Reply:

Similar Artilces:

How can I modify the "Type definitions" of "Function Prototype" if I want build a DLL in Labview 8.5.1.?
Hello,We have a library with several VIs (API - Interfaces to our Real Time Target). This VIs we provide to our customer to generate own VIs to control the Real Time Target.Now we want to provide the functionality of this VI-library as DLL to our customer. The problem is, that labview use self definite name of type definitions. Also if I use "strict Type definition".Example:void GetOutputValues(VARIANT *Scale_In, int32_t ModelNr, uint16_t SignalID[], TD1:smileymad: *errorIn, VARIANT *Scale_Out, TD2 *Data, TD1 *errorOut, int32_t len)It is possible to modify "TD1" and "TD2"? I want to give useful names.GreetingsSteffen Hi Steffen,       Try editing the .h file as follows: CHANGE FROM: typedef struct { LVBoolean status; long code; LStrHandle source; } TD1; CHANGE TO: typedef struct { LVBoolean status; long code; LStrHandle source; } TD1; typedef struct { LVBoolean status; long code; LStrHandle source; } LVErrorCluster; then your GetOutputValues prototype becomes: void GetOutputValues(VARIANT *Scale_In, int32_t ModelNr, uint16_t SignalID[], LVErrorCluster *errorIn, VARIANT *Scale_Out, TD2 *Data, LVErrorCluster *errorOut, int32_t len) If your source-code doesn't refer to "TD1", then you probably won't need to keep the TD1 prototype! Cheers. ...

error 7 in "application builder" for LabVIEW 8.5.1
Hello,   I am getting an error while building a project for making EXE file.   below is the displayed message.   Error 7 occurred at Copy in New VILibrary.vi->AB_Dest_LLB.lvclass:Create_Destination.vi->AB_Build.lvclassLCreate_Destinations.vi ->AB_Build.lvclasss:Build.vi->AB_EXE.lvclass:Build.vi->AB_Engine_BUild.vi->AB_Build_Invoke.vi->A B_Build_Invoke.vi.ProxyCaller   ============================NI-488: Non-existent GPIB interface. C:\ProgramFile\NationalInstruments \LabVIEW8.5\vi.lib\Utility\libraryn.bin   thanks,   You can force LabVIEW to recompile the entire VI hierarchy in your project with CTRL+SHIFT+Run Button. Have you imported some old VI's into the project?  From a previous version? Did you add files since creating the build parameters?  You may want to delete the build parameters and create a new one. RayRMessage Edited by JoeLabView on 07-02-2008 08:35 AM Also, check the path of the reported missing file and make sure it really isn't missing. Thanks George...  :) Especially if code moved around (Copy / Paste to another folder / backup, etc..) Thanks Ray and George, I was using VIs of 7.1 version for 8.5 builder. I deleted the previous build parameters and created a new one, it was sucessful. - sriveni   Glad it worked.. :) ...

Labview 8.5.1's MathScript window failed running imread with an error "A problem occurred in a subVI call."
Hi, I am trying to port a Matlab program into a MathScript script.&nbsp; Following is the first few lines of the script:clear;image1=imread('C:\LV_VertAlign\DSC_0104.jpg','jpg');image_double1=im2double(image1);image_gray11=rgb2gray(image_double1);In the first line, imread is supposed to read in a photo taken from a DSLR camera, so I think it's a 32-bit image.&nbsp; And this is the error I got when trying to run this script in the Labview 8.5.1's Mathscript windows:"Error in function imread at line 2.&nbsp; A problem occurred in a subVI call."What is the problem here?&nbsp; and why does it complain about a subVI call?Thanks for any help to point me in the right direction.-Anh Hi Anh, &nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; We have documentation on many of the MathScript functions available in LabVIEW.&nbsp; You can look at a document <a href="http://zone.ni.com/reference/en-XX/help/371361D-01/lvtextmath/msfunc_imread/" target="_blank">here</a> that describes how to use the imread function.&nbsp; This is searchable from ni.com by entering the function name.&nbsp; If you read this document you will see the second parameter of the function only accepts the following arguments : 'BMP', 'JPEG', 'PNG'.&nbsp; If you change your line 2 to : image1=imread('C:\LV_VertAlig...

LabVIEW 8.5.1 &quot;The build was unsuccessful&quot;
When attempting to build my executable in LabVIEW 8.5.1 I get the following dialog: &nbsp; <img src="http://forums.ni.com/attachments/ni/170/338657/1/Build%20Errors.PNG"> &nbsp; I've tried recreating my build specification, reinstalling LabVIEW, commenting out sections of my code and nothing seems to help.&nbsp; Has anyone encountered this before?&nbsp; Any ideas NI?Message Edited by FlamingYawn on 07-08-2008 11:24 AM Build Errors.PNG: http://forums.ni.com/attachments/ni/170/338657/1/Build Errors.PNG Hi, &nbsp; Are you building a .exe application? In that case, please verify that all your startup and always included VIs exist in the same path and have been properly compiled. You can try Tolls&lt;VI Analyzer&lt; Mass Compile. Also are you using DSC or shared variables in your code? &nbsp; Ipshita C. Hi Ipshita, &nbsp; Thanks for responding.&nbsp; &nbsp; Yes, this is "a .exe application."&nbsp; &nbsp; My startup path is correct, and I tried building with all my "always included" VIs removed.&nbsp; Same error. &nbsp; I've mass compiled several times. &nbsp; I'm not using DSC or shared variables. &nbsp; I'm able to build the executable on another computer with the exact same project and code (we use source code control), so something must be different about my environment or setup. &nbsp; Thanks, &nbsp; Robert I have seen this error before, but ...

Labview 8.5 error on save: &quot;Cannot load help information of [filename].&quot;
Hi all, &nbsp; &nbsp;I was working on a VI in Labview 8.5 when the program (Labview) crashed. When I relaunched Labview it asked me if I wanted to recover the VI&nbsp;I was working on,&nbsp;I said yes and the recovered VI runs fine, but I cannot save it. When&nbsp;I try to Save or Save As I receive the following error message: "Cannot load help information of [Filename]" and my only option is "Cancel Save". If I click "Cancel Save" Labview returns a "File not Found error". Until the recovery, I could and did save the file with no problems. It now seems that I am locked out of the file. &nbsp; &nbsp; I have a backup, but it is does not contain the 2-3 hours of work I put in before the crash. Does anyone have a work-around, or know the source of this error? This is the second time I have seen it on a recovered file (the first time I had a fresh backup, so it wasn't a big issue). &nbsp; Here is a dump of the "Referencing files in the project or its dependencies" from the Save As dialog: &nbsp; [Project Name].lvprojreplay2-offsets.vi:Instance:6replay2-offsets.vi:Instance:5replay2-offsets.vi:Instance:3replay2-offsets.vi:Instance:2replay2-offsets.vi:Instance:4replay2-offsets.vi:Instance:1replay2-offsets.vi:Instance:0 &nbsp; Thank you, Tim I'm having the same problem. I came here to see if there was any information about this problem, and found the previous message. Lucky for me, I&#...

Error 1047 in LabVIEW 8.2: LabVIEW failed to send variable to the script server. Server:&quot;&quot;
I am working with the evaluation version of labVIEW as well and I have run into another error.&nbsp; I am using a MATLAB script node within a for loop and attempting to pass the for loop counter variable into the script.&nbsp; When I run the code it brings up a 1047 error and says "LabVIEW failed to send variable to the script server. Server:"" ".&nbsp; I looked up the error online which seems to have roots in a failed auto initialization of MATLAB.&nbsp; Is there something that I can do in labVIEW to fix the problem or is it strictly a MATLAB error? &nbsp; I really appreciate your help. Hi Patsenat, &nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; We have a knowledgebase document on our system referring to this issue.&nbsp; Try reading through <a href="http://digital.ni.com/public.nsf/allkb/2B3FF46C8512C4F786256CF30071BE53?OpenDocument" target="_blank">this</a> and attempting what it says.&nbsp; If you still have problems, please post again. ...

why it keeps on asking &quot;NI LabVIEW 8.5.1&quot; distribution when building installer?
Hi, I am building an installer for one image processing application. For addtional installers, NI Labview runtime engine 8.5.1NI vision runtime engine 8.5NI IMAQdx 3.1.2NI VISA runtime 4.3When building, it keeps on asking "NI LabVIEW 8.5.1" distribution even though I put the CD into CD room, saying it needs to copy a component installed or updated by the distribution to continue building the installer.If&nbsp; NI-IMAQ dx 3.1.2 not checked, it is OK. BUT, I need it.Thanks a lot for any help.Anne Zuo What is a "CD room"? or CD driver. sorry for my language.&nbsp; Take a look at this <a href="http://forums.ni.com/ni/board/message?board.id=170&amp;view=by_date_ascending&amp;message.id=210032#M210032" target="_blank">link</a> and see if it helps. &nbsp; Also, if it doesn't like disk 1, put in disk 2 instead, if not disk 2, then try disk 3.&nbsp; Perhaps it is looking for the driver it needs, but the actual files it is looking for is on the 2nd or 3rd CD. &nbsp; Ultimately, it may be best to copy all of the CD's to your hard drive and have it point to them there. ...

Build error after upgrading from 8.2.1 to 8.5 &quot;Error 1055 occurred at Invoke Node...&quot;
After upgrading to 8.5, I'm getting the following error when trying to build an EXE: &nbsp; Visit the Request Support page at ni.com/ask to learn more about resolving this problem. Use the following information as a reference: Error 1055 occurred at Invoke Node in AB_Source_Library.lvclass:Close_Reference.vi-&gt;AB_Build.lvclass:Copy_Files.vi-&gt;AB_Application.lvclass:Copy_Files.vi-&gt;AB_Build.lvclass:Build.vi-&gt;AB_EXE.lvclass:Build.vi-&gt;AB_Engine_Build.vi-&gt;AB_Build_Invoke.vi-&gt;AB_Build_Invoke.vi.ProxyCaller Possible reason(s): LabVIEW:&nbsp; Object reference is invalid. I have been building this application for both Windows and Mac OS, and I even get the same error when building the&nbsp;.app&nbsp;on an Intel Mac. Things that I've already tried: *&nbsp;Mass-compiling all my code * Created the project from scratch * Enabled each panel of the "diagram disable structure" one at a time&nbsp;and compiled again &nbsp; Any ideas? I think I saw that in LV 8.2.1 after upgrading from LV 8.2 I did a repair on the nistall and that cleared up the problem. You may want to try that. Ben You mean a repair of the NI installation of LV8.5?&nbsp; But I had the same trouble on a Mac OS machine too.&nbsp; Seems unlikely that an installation glitch could explain the problem on such different platforms.&nbsp; (For the record, I tried on both a Win2K machine and an XP machine--a total of 3 different ...

Error Code &quot;1097.....this might corrupted LABVIEW's memory..........&quot; appears after exit the labview and re-start labview
&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;I have a probelm when I use the "tool/import shared library(.dll)" wizard&nbsp;to generate the&nbsp;API from C. &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; The API &nbsp;works correctly when I complete the wizard, but after I exit labview and re-start labview to run&nbsp;the API&nbsp;again. The error 1097 code "......this might corrupted LABVIEW's memory.............."appears. &nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;The only solution now is to re-generate or update the wizard to&nbsp;generate the API. &nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;I try to find the answer in &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; <a href="http://digital.ni.com/public.nsf/allkb/58596F5D41CE8EFB862562AF0074E04C?OpenDocument" target="_blank">http://digital.ni.com/public.nsf/allkb/58596F5D41CE8EFB862562AF0074E04C?OpenDocument</a>&nbsp; &nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; The paragraph in above article shows ........................... &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; "LabVIEW does not crash until it is closedThe most likely problem is that the DLL function being called has corrupted th...

Labview &quot;Fatal Internal Error &quot;memory.cpp&quot; line 1038
Hi, &nbsp; This is an example file provided by NI and can be found in Labview 8.2\examples\instr\niHSDIO: Dynamic Generation.lib. Inside this library, there is a file called "Dynamic Generation.vi". If I copied "Dynamic Generation.vi" to other place, the labview will crash. Error message: &nbsp; "Fatal Internal Error. "memory.cpp". Line 1038. Labview version 7.1.1. You will lose any unused work, please contact NI, etc, etc" &nbsp; In the mean time, the Windows freeze. Mouse right click no response. No status bar at the bottom of the screen. The whole desktop is blank. All icons on the desktop disappeared. I have to log-off and re-login to re-active everything. &nbsp; I also tried to copy&nbsp;other VI's in other library files. Same thing happened. &nbsp; Thanks, Jing I&nbsp;was using Labview 8.2.1 when I had this crash, though I have Labview 7 installed in the same computer. When I "copy the file to some other place", I mean: Click the *.vi file, ctrl-c and ctrl-v to some other directory. Thanks, Jing ...

Adding an &quot;IMAQ Image.ctl&quot; to the &quot;Display State.ctl&quot; of an XControl prevents LabVIEW from creating a probe of &quot;Display State.ctl&quot;
I am working on an extended IMAQ Display control using LabVIEWs XControl capabilities. &nbsp; I need a copy of the original image passed to add some overlays which must not affect the original image. To achieve this I am creating a backup image in the "Init.vi" and deleting it in the "Uninit.vi". I am storing the reference&nbsp;of this image&nbsp;in the "Display State.ctl" which is part of every XControl. &nbsp; As soon as I am adding an "IMAQ Image.ctl" to the Display State cluster, it is no longer possible to generate a probe of the Display State cluster for debugging purposses. I am always getting the message: "Failed to load or create probe." Deleting the "IMAQ Image.ctl" from the cluster makes the probe working again. &nbsp; Is it a bug or am I doing something wrong? &nbsp; I am working with LabVIEW 8.5 and Vision 8.5. &nbsp; Regards &nbsp; Ingo Bartsch Hello Mr. Bartsch, is it possible for you to post a small example to reproduce the behaviour? It would be helpful to get a description in which way you use the typedef files. I found a example/knowledge base where some informations were included to XControl and LV but not with Vision. <a href="http://digital.ni.com/public.nsf/allkb/1DC1ADD2A136DA298625712C00635758?OpenDocument" target="_blank">http://digital.ni.com/public.nsf/allkb/1DC1ADD2A136DA298625712C00635758?OpenDocument</a> Best wishes Ja...

plug-in &quot;not installed&quot; in my LabVIEW project's &quot;Build Specifications&quot;
I moved my LabVIEW project from one computer to another, now when I click on any item under the project's "Build Specifications", I get an error reading "The plug-in for the selected item is not installed on your system." Does anybody know how to fix this? I have no idea what this "plug-in" is.Attached is a screenshot. plug-in error.PNG: http://forums.ni.com/attachments/ni/170/222664/1/plug-in error.PNG ...

Memory is full during &quot;Save As&quot; of LabVIEW 8.5 project
Good Morning All, &nbsp;&nbsp;&nbsp;&nbsp; Have run into a weird issue while trying to rename a LabVIEW 8.5 project. I've got two projects that ended up having the same names (one by me, one by another engineer). I want to open both at the same time, so I figured I'd open the one and do a "save as", or a "rename". The first time it started processing, doing file loads, and then hung looking for a sub-vi, with the search address pointing to the .llb in the LV 8.5 directory where I manually located it. Once that was resolved, and the original project saved I tried again. This time it did a bunch of loading and then gave me an error box with the message:&nbsp; "LabVIEW:&nbsp; Memory is full.&nbsp; Cannot save project 'original project name.lvproj'" This isn't a big project, the machine is a new HP Compaq dual core 2.8GHz with 1.5Gb of ram, so I don't really think that it should be generating anything that big. This happens with either a "save as" or "rename". I ended up just changing the names of the .lvproj .aliases files to the one I needed and it seems to load ok, but it would be nice to understand what is happening here. &nbsp; &nbsp; This is interesting behavior, since NI actually ensured that you would now have the ability to Save As and Rename a project with the <a href="http://www.ni.com/pdf/manuals/371780c.pdf" target="_blank">release ...

&quot;IDDCO ERROR&quot; for Labview 8.0 and Keithley 6487 picoameter
Hi all, I have a 6487 keithley picoameter and I would like to take current mesurements using labview 8.0. What I tried to do is to built a very simple vi with two instrument I/O assistants (one for configuring the picoammeter and another to take measurments as it changes voltage). I have accompliced the same thing in Visual Studio with C#. The problem is that although some times I do get correct measurements there is always one, two or three IDDCO ERROR idications which I do not know what they mean.&nbsp; I can only tell that this does not happen at the same voltage value but it seems rather random. What is wrong? I have attached the vi if anyone is interested. Thanks in advance for any helpAndreas V_bias_test.vi: http://forums.ni.com/attachments/ni/170/324015/1/V_bias_test.vi According to <a href="http://www.keithley.com/search?searchType=general&SearchableText=IDDCO" target="_blank">Keithley</a> , "This error means the instrument received an Illegal Device-dependent Command Option.". I have not used this model Keithley or DDC. One thing you should do is wire the error out of the initialize Instrument Assistant to the for loop to assure that is actually runs before the for loop. ...

How can I convert the &quot;AI one pt&quot; symbol from LabVIEW 6.3 to LabVIEW 8.0?
Hi, &nbsp; I've got an assignment with LabVIEW and&nbsp;I work with LabVIEW 8.0. The program I work with is written in LabVIEW 6.3 and had to be converted&nbsp;to LabVIEW 8.0. That went very well, except for one symbol. The "AI one pt" symbol (see&nbsp;enclosed figure) turned into an empty box (question mark). My question to you is how can I overcome this problem, or how can I simulate this symbol with LabVIEW 8.0? &nbsp; With kind regards, &nbsp; Sander Smeets &nbsp; <img src="http://www.ese.upenn.edu/rca/software/Labview/labview41/inputoutput/AISamplechannel.gif"> Hello, Graziano is right about this. To make it completly clear: The block you refer to as a symbol is a VI belonging to the Traditional NI-DAQ driver. Currently there are two drivers for DAQ boards: DAQmx (the new one) and Traditional NI-DAQ (the old one). Since your VI was written in LabVIEW 6.x (6.3 never existed) the VI uses the old driver. What you need to do is: install Traditional NI-DAQ on your PC to get the support VI's for the driver in LabVIEW. This Traditional NI-DAQ installer&nbsp;should be on the driver CD which was delivered along with LabVIEW 8.0 or you can download it here: <a href="http://joule.ni.com/nidu/cds/view/p/id/586/lang/en" target="_blank">http://joule.ni.com/nidu/cds/view/p/id/586/lang/en</a> There is one good point though which Graziano already mentioned: Which DAQ board are you using? I...

How to remove the &quot;int len&quot; of my return string on the DLLS header when building a DLL on LabVIEW 8.5
Hi all. I'm building a DLL on LabVIEW and I choose a string as an output on the terminals connectors. But LabVIEW creates another output, the lenght of the return string. This is a problem because I have other DLLs and&nbsp;I need them to be compatible. How do I remove this length from the header? What is the difference between Pascal String and C string and String Handle Pointer? String Handle Pointer removes the length from the header but I don't know the difference between this data types. Thanks in advance for the help. &nbsp; Daniel Coelho Portugal &nbsp; Daniel Coelho wrote:Hi all. I'm building a DLL on LabVIEW and I choose a string as an output on the terminals connectors. But LabVIEW creates another output, the lenght of the return string. This is a problem because I have other DLLs and&nbsp;I need them to be compatible. How do I remove this length from the header? What is the difference between Pascal String and C string and String Handle Pointer? String Handle Pointer removes the length from the header but I don't know the difference between this data types. Thanks in advance for the help. &nbsp; Daniel Coelho Portugal &nbsp;C string pointer is a pointer to a memory location whose string information is terminated by a 0 byte. Pascal String Pointer is a pointer to a memory location where the first byte specifies the number of bytes to follow. This obviously allows only for strings up to 255 character length.LabVIEW String Hand...

Where can I get example code &quot;Row Col to Range format.vi&quot; for LabVIEW 5.1?
In the example code section, there is a VI called Row Col to Range format.vi, but it is for LabVIEW version 8 and will not work with Version 5.1 that I have.&nbsp; Somehow, we have misplaced this VI and I cannot change the existing .EXE that uses this VI without it. Thanks for your help. Hi tater Here's a copy of Row Col to Range Format.vi in LabVIEW 5.1.&nbsp; (I changed the name to reflect that it is in this specific version.&nbsp; You will need to change it back.) Best of luck,Kevin S.Applications EngineerNational Instruments Row Col To Range Format, v5-1.vi: http://forums.ni.com/attachments/ni/170/347310/1/Row Col To Range Format, v5-1.vi ...

&quot;Invalid Drive&quot; error while installing LabVIEW
&nbsp; Installing LabVIEW 6.1 on an NT4 machine with administrator previldeges. &nbsp; Comes up with error "Error 1327 : Invalid drive H:\"&nbsp; ....Dialog Box 1 &amp; then "Error 1603 occurred while installing NI LabVIEW 6.1. Continue installing other products ?" ..... Dialog Box2 &nbsp; Same thing happens while installing RunTime Engine 6.1 &nbsp; Error messages included in attached file. &nbsp; Any insights? &nbsp; Thanks &nbsp; &nbsp; &nbsp; Invalid Drive Error While Installing LabVIEW.doc: http://forums.ni.com/attachments/...

Re: VisualBasic &quot;Show &amp; Hide&quot; equivalents in LabView
Hi, I want to show/hide the Labview Help programatically. (Just on the click on single button) How it can be done? Do i have to use event structure on Ctrl + H buttons???:smileyindifferent: Please suggest some solution. Thanks There's a help palette with a primitive called Control Help Window, which should do what you want (assuming you want the context help). <img src="http://forums.ni.com/attachments/ni/170/336539/1/untitled5.PNG"> Message Edited by mathan on 07-01-2008 07:07 AM untitled5.PNG: http://forums.ni.com/attachments/ni/170/336539/1/untitled5.PNG Hi Tst, Thanks. i know that there is a Context Help Window where you can see the help for all the functions or Labview help. i want to show/hide this window programatically. Is it possible? Thanks. Thanks Mathan, This is what i wanted. Thanks. Hi Dev, the first of those functions ("context help window") is what you need - as you can read in the context help window for that function!!!:smileyvery-happy: Yes, i got it. thanks . ...

&quot;re-entrant&quot; &quot;file I/O&quot; &quot;QSM_State Machines&quot;
&nbsp; &nbsp; I have trouble with writing (appending) to text file in a QSM that is in an "occurence mode" of operation whereby the queue waits for outside engueue to go ahead and do a task. The task is simply to write to a file a line of text. &nbsp; Outside producers give the queue its go ahead and data is sent along etc... &nbsp; WHat I am seeing in the logging functions are multiple errors (Error 1) Somehow Labview&nbsp;is not noticing that the reference is valid or it is invalidating the reference. &nbsp; Q is Should I just let the QSM loop to keep it alive and would that work? &nbsp; What is the rule concerning queue waiting for an event? Does the VI get flagged as idle and is that why the ref appears to be dropped?&nbsp; THere is no reason I can think of for the ref to be dropped. It is opened in the init frame then kept in a shift register. and available at each iteration in the QSM. &nbsp; The example works in a simple loop but not a loop that is waiting on an occurence.&nbsp; Why? &nbsp; The only work around I can manage is to use the path and open the reference when it is not valid which feels kind of&nbsp; silly if you get my drift &nbsp; Anyone seen this before? &nbsp; Thank You &nbsp; &nbsp; &nbsp; ...

Error -50150 &quot;Cascade Failure&quot;: LabVIEW Bug?
Hello, &nbsp; I'm new to the forums here, so I apologize in advance for breaches of etiquette or various other newbie actions. ;) &nbsp; While using the DAQmx Create Channel VI in conjuction with my own custom unit scale, I keep running into a -50150 error for various combinations of slope and y-intercept. I've pared my problem down to the attached VI. As you can see, I'm setting up the linear scale with a slope and y-intercept, and then scaling the original +/- 10V range for&nbsp;an appropriate&nbsp;maximum and minimum. Upon running this VI as-is, I get the -50150 "cascade failure" error. However, changing the y-intercept value to an arbitrarily different value, say 6, causes the program to run fine. &nbsp; I've noticed that other combinations of slope-intercept also crash the program, and that these combinations usually have a pattern. For example, the (m, b) combinations of &nbsp; (100,5); (100,20); (100,30); (100,45); (100,55); (100,70); and so on, with the 10-15-10-15 pattern repeating &nbsp; cause the program to throw -50150 as well. I have not found any values of the y-intercept that cause the program to crash that are not&nbsp;multiples of 5 (although obviously I cannot say conclusively that there are none). I realize that it is all very well for me to claim that this is a software bug and not my fault, but I cannot see any good reason for this to be happening in such an odd way. &nbsp; I am running LabVIEW...

LV8,5 Dev Suite install, error &quot;Measurement Studio for VS2003 not installed&quot;&quot;
Hi guys, &nbsp; Installing LabVIEW 8.5 Developers suite, installed LV8,5 OK, but all otehr products (CVI, Studio, etc) come up with error messages as per attached photo, "measurement Studio for VSXXXX not installed" &nbsp; When should I have installed this ? which DVD has this ? &nbsp; Any help apreciated &nbsp; Cheers &nbsp; Mathew LV8.5Install.GIF: http://forums.ni.com/attachments/ni/170/272665/1/LV8.5Install.GIF Thanks for the replys. The thing is,I have brought the Developers Suite www.ni.com/suite/ ($7070 NZD),which includes the CVI toolkit&nbsp; and a whole lot of other stuff, surely the required 3rd party software required should be included in the package ? Will give the install anther go, using default settings and see what happens Message Edited by Matwelli on 09-18-2007 11:58 PM ...

LabVIEW crashed when openning XControl Facade, and Init VI
XControl_Fatal error.PNG: http://forums.ni.com/attachments/ni/170/261642/1/XControl_Fatal error.PNG XControl_Fatal error1.PNG: http://forums.ni.com/attachments/ni/170/261642/2/XControl_Fatal error1.PNG ...

&quot;LabVIEW load error code 3&quot; USB drive
Hi Folks, &nbsp;&nbsp;&nbsp;&nbsp;&nbsp; I'm not expecting any solution here, though it would be nice... &nbsp; Twice, recently, I've lost a top-leve VI due to the error below.&nbsp; I suspect the problem is related to working off a new USB drive - a 2G Lexar Firefly.&nbsp; For&nbsp;two or three years a Lexar Jumpdrive Elite (256M) served me flawlessly, after moving to the Firefly ~2 weeks ago, this error&nbsp;has happened twice.&nbsp; BTW,&nbsp;the Firefly is also extremely slow -&nbsp;amazingly&nbsp;slow, considering how much newer it is. &nbsp; If any wiz-kids have dissected the&nbsp;VI binary well enough to, possibly, identify/repair problems, it would be very much appreciated! &nbsp; <img src="http://forums.ni.com/attachments/ni/170/291448/1/LoadErrorCode3.JPG"> &nbsp; Cheers!Message Edited by tbd on 12-19-2007 09:45 PM LoadErrorCode3.JPG: http://forums.ni.com/attachments/ni/170/291448/1/LoadErrorCode3.JPG Hi Phillip, &nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Thanks for the heads-up re:&nbsp;background-apps slowing-down drive.To be honest, I don't know how to find/disable such apps. but now know to look. Re:&nbsp;Lexar Firefly - it's&nbsp;slow by design, though there's no warning on the package when you buy it.&nbsp; Here's the response from their Customer Support: " Jumpdrive Firefly is a non-speed rated Jumpdrive and is made...

Web resources about - LabVIEW RT 8.5.1 &quot;reboot due to system error&quot; - comp.lang.labview

Resources last updated: 3/19/2016 9:35:13 AM