I have an Infortrend 3102 RAID array connected to a Sun Ultra60
running Solaris 8.
Inside the RAID array I have 7 physical SCSI drives. From these, I've
created 1 RAID 5 configuration, 1 RAID 1 configuration, and another
RAID 1 configuration, all as Logical Drives.
From there I created 3 Host LUN's, 1 LUN for each Logical Drive.
Here' the problem, I only see 1 LUN after Solaris boots up.
Details:
At the open boot prompt, I see all three Logical Drives (using
probe-scsi-all). They are listed as follows:
/pci@1f,4000/scsi@3,1
Target 0
Unit 0 Disk 3102 0223
Unit 1 Disk 3102 0223
Unit 2 Disk 3102 0223
I also see the internal drive and the CD-ROM as additional SCSI
targets.
Dmesg reports only 1 Logical Drive
Jun 25 08:35:47 helles pcipsy: [ID 370704 kern.notice] PCI-device:
scsi@3,1, glm1
Jun 25 08:35:48 helles genunix: [ID 936769 kern.notice] glm1 is
/pci@1f,4000/scsi@3,1
Jun 25 08:35:48 helles scsi: [ID 193665 kern.notice] sd15 at glm1:
target 0 lun 0
Jun 25 08:35:48 helles genunix: [ID 936769 kern.notice] sd15 is
/pci@1f,4000/scsi@3,1/sd@0,0
Jun 25 08:35:48 helles scsi: [ID 365881 kern.notice] <IFT-3102-0223
cyl 35092 alt 2 hd 64 sec 32>
Jun 25 08:35:48 helles scsi: [ID 193665 kern.notice] sd1 at glm0:
target 1 lun 0
Jun 25 08:35:48 helles genunix: [ID 936769 kern.notice] sd1 is
/pci@1f,4000/scsi@3/sd@1,0
Jun 25 08:35:48 helles scsi: [ID 365881 kern.notice] <SUN36G cyl
24620 alt 2 hd 27 sec 107>
Jun 25 08:35:50 helles scsi: [ID 193665 kern.notice] sd6 at glm0:
target 6 lun 0
Jun 25 08:35:50 helles genunix: [ID 936769 kern.notice] sd6 is
/pci@1f,4000/scsi@3/sd@6,0
Jun 25 08:35:53 helles swapgeneric: [ID 308332 kern.notice] root on
/pci@1f,4000/scsi@3/disk@1,0:a fstype ufs
Jun 25 08:35:53 helles pcipsy: [ID 370704 kern.notice] PCI-device:
ebus@1, ebus0
Jun 25 08:35:53 helles ebus: [ID 521012 kern.notice] su0 at ebus0:
offset 14,3083f8
Jun 25 08:35:54 helles genunix: [ID 936769 kern.notice] su0 is
/pci@1f,4000/ebus@1/su@14,3083f8
Jun 25 08:35:54 helles ebus: [ID 521012 kern.notice] su1 at ebus0:
offset 14,3062f8
Jun 25 08:35:54 helles genunix: [ID 936769 kern.notice] su1 is
/pci@1f,4000/ebus@1/su@14,3062f8
Jun 25 08:35:54 helles pcipsy: [ID 370704 kern.notice] PCI-device:
SUNW,m64B@2, m640
Jun 25 08:35:54 helles genunix: [ID 936769 kern.notice] m640 is
/pci@1f,4000/SUNW,m64B@2
Jun 25 08:35:54 helles m64: [ID 308573 kern.notice] m64#0: 1152x900,
2M mappable, rev 4754.9a
Jun 25 08:35:54 helles unix: [ID 987524 kern.notice] cpu0:
SUNW,UltraSPARC-II (upaid 0 impl 0x11 ver 0xa0 clock 4
50 MHz)
I don't really know that much about SCSI Channels, but the phyiscal
SCSI drives report being on either SCSI Channel 1 or SCSI Channel 2.
Any help would be greatly appreciated. Thanks for your time.
charlie
|