US3D Storing FAN Shaped volume0147 (11/27/2009 6:28:50 AM) Hi,
Is it possible to store FAN Shaped 3D volume (frames are stored with
angle as distance, so cannot encode it as spatial) using DICOM
(supplement 43).
I found the below information from the supplement... sanjay.nm(2)
DICOM vs .. "raw DICOM" ?2794 (11/24/2009 6:54:27 PM) I'm looking at this sentence:
"Access and store images in DICOM or raw data DICOM formats to meet
medical digital communication standards "
It comes from here: http://www.gehealthcare.com/euen/ultrasound/ult... trevoke(5)
Import Scan Images to DICOM as Open Source Application11325 (11/23/2009 1:21:13 PM) Hello c.p.d.,
in a current project, I am looking for an Import Application for
clinical use that imports non-DICOM scan Images to a DICOM PACS.
I could not find a suitable Software by now - but I think i... Peter
Patient Name = NULL in C-FIND Patient Root, Study level4156 (11/20/2009 1:39:14 PM) I have tried to find rules in the Dicom standard that specifies what
attributes can be used in a C-FIND Patient Root Query level = STUDY on
the Patient level. Of course the Patient ID must be specified. But i... Huub
Cross Platform Dicom Viewer - MAYAM8958 (11/5/2009 7:22:44 AM) Hi guys
MAYAM is a Cross platform dicom viewer developed in
JAVA. do try it out
Viewer Features
1. DICOM Listener for Q/R
2. DICOM Send
3. Local DB for storing study informa... babuhussaina(1)
Why not UDP?5131 (11/16/2009 5:09:50 PM) Hi,
Why don't we see DICOM applications sending throuh UDP ports ? is that
part of the standard ?
regards,
Q8PACS admin
... Q8Pacs
Grayscale Presentation State and RGB data2402 (11/17/2009 9:33:17 PM) 1) Is it legal to have a GSPS object for a US image if Photometric
interpretation="RGB" and "Ultrasound Color Data Present"= 00
( which says the pixels are grayscale encoded as RGB) ?
2). Is it legal to ... stvnmnnr(1)
how to handle duplicated attributes?5120 (10/27/2009 8:05:40 PM) I am using Enhanced CT Image IOD Modules. I found the Table C.8-131
(Common CT/MR Image Description Macro) are included at least twice:
one in Table C.8-117 and one in Table C.8-114. There are also few
other... dicomLearner
tag fffe,e0001211 (11/16/2009 9:20:37 AM) I used Merge to remove tags REFERENCED_SOP_CLASS_UID,
REFERENCED_SOP_INSTANCE_UID and REFERENCED_FRAME_NUMBER under
REFERENCED_IMAGE_SEQUENCE from PR.
But when I load the PR it shows an item fffee000 in th... Manu
Is compressed pixel data in unencapsulated format valid?2175 (11/12/2009 1:30:08 PM) We have received a sample image from a customer that is compressed
using JPEG lossless non hierarchical 1st order prediction transfer
syntax and includes the pixel data in unencapsulated format, without
enco... m.doppler(2)