f



From a AS400 with a CCSID to another AS400 with different CCSID

Hi all,

I've the following issue:

- I have to move data from a AS400 with CCSID 65535 (no conversion) to
another AS400 with CCSID 37

I'm using DDM files on the second AS400 linked to the first AS400, but
reading DDM files I have the problem that data are different in the
special characters...

So I changed my job session CCSID to 65535 with CHGJOB; with that I
can see correctly DDM files data, but not the local files...

What do you suggest to do?

Many thanks in advance.
Fabrizio
0
bonfab (6)
6/9/2011 12:47:34 PM
comp.sys.ibm.as400.misc 9219 articles. 3 followers. Post Follow

1 Replies
1608 Views

Similar Articles

[PageSpeed] 19

On 09-Jun-2011 05:47 , Fabrizio wrote:
>
> I've the following issue:
>
> - I have to move data from a AS400 with CCSID 65535 (no conversion)
> to another AS400 with CCSID 37
>
> I'm using DDM files on the second AS400 linked to the first AS400,
> but reading DDM files I have the problem that data are different in
> the special characters...
>
> So I changed my job session CCSID to 65535 with CHGJOB; with that I
> can see correctly DDM files data, but not the local files...
>
> What do you suggest to do?
>

   The system CCSID QCCSID is effectively moot in that scenario as far 
as I can recall.  What do matter are the CCSID of the job opening the 
file and then reading the data, and the CCSID of the columns of the file 
being opened.  When the job is set to a proper CCSID, then whenever the 
data is also "tagged" properly with a CCSID [e.g. column of a table with 
a non-hex (non-65535) CCSID], the database will convert the data which 
can then be displayed properly.

   Since the data from the DDM-target system appears properly at the 
DDM-source system when the CCSID in the local job is set to something 
other than *HEX suggests that the target database files probably have 
the CCSID tagging, and probably set properly.  And because data accessed 
from local database files appears incorrect when the CCSID is set to a 
non-hex value suggests that the local database files also probably have 
CCSID tagging, but probably set improperly.

   The correction depends on the data being properly tagged, and that 
programs honor the tagging by avoiding use of the *HEX CCSID.  I would 
start by reviewing the actual field [column] CCSID settings on a small 
set of production files, verifying that the data matches or does not 
match the CCSID.  Then I would review what actions need to take place to 
enable that all file, data, and user profiles [explicitly set each with 
a non-hex CCSID()] changes can be performed some night in order that the 
applications will be functioning as expected the next day; much easier 
said than done.

Regards, Chuck
0
crpence (662)
6/9/2011 3:24:15 PM
Reply:

Similar Artilces:

AS400 to AS400 connection
Hi. What`s the rocommended method of copyting data beetween two AS400 (both on V5R1) ? Regards, Tom tom wrote: > Hi. > What`s the rocommended method of copyting data beetween two AS400 (both on > V5R1) ? Probably FTP. "tom" <tomeks@comp.pl> wrote in message news:c8c9u5$fb4$1@nemesis.news.tpi.pl... > Hi. > What`s the rocommended method of copyting data beetween two AS400 (both on > V5R1) ? > > Regards, > Tom > > It depends how often you are doing the copying & how much there is. If you want say one record but every 3 seconds then you can either store them up for a few hours days or weeks & use FTP, snads or a tape. Or you can do it realtime & use DDMF to zap each record to the other machine as its written. I actually save the data I want sending this way into a file which is read & deleted by a daemon style of job so that if comms or the other machine fails only the daemon is affected. FTP has its upside in that the target is easily resettable for say a unix machine but SNADS has an easy to use & understand message sent to the sender & recipient to verify arrival of the data. -- Jonathan Bailey. You could install the No Charge SW "Object Connect" from the OS CDs. Once setup you can issue cmds line SAVRSTLIB and SAVRSTOBJ. Give these cmds the LIB or OBJ list and the target system. It then saves/transfers/restores to the target system all with just the 1 SAVRSTxxx cmd. tom wro...

Printing on AS400 via IBM AS400 Java Toolkit
Hello all, I'm working on a program that needs to send a print job to a printer connected to an AS/400. I've tried using the SpooledFileOutputStream and I've also tried using one of the SCS Writer classes. Neither solution is working. With the SpooledFileOutputStream I am at least able to create my print file, but when my program ends, the file is still not being printed. This program does not run on the AS400, it runs on a PC and connects to the AS400 via the toolkit classes. I know this part works as I am able to use the toolkit to access Data Queues, Files and Data Areas without a problem. Is there anyplace anyone can point me to see some examples of how to print a file using the AS400 Java Toolkit? Thanks in advance, Chuck Chuck, What printer data stream is used? or how was the printer data generated? I am wondering if the data stream being generated matches the data stream of the printer connected to the iSeries? What printer is attached to the iSeries and how is it configured? The iSeries info center has some Toolbox examples: Programming>Java>IBM Toolbox for Java>IBM Toolbox for Java Classes> Access Classes>Print>Creating... Dave Chuck wrote: > Hello all, > > I'm working on a program that needs to send a print job to a printer > connected to an AS/400. I've tried using the SpooledFileOutputStream > and I've also tried using one of the SCS Writer classes. Neither > solution is working. With the Sp...

AS400 to AS400 connection issues
Hi All, We have two AS400's at different locations, and were able to passthrough and send files between both no problems. Last week one of our AS400's was moved to another location, with an IP change. We have updated the IP addresses on the other AS400 and can passthrough fine....however we can no longer send files from the new location. When I look at the distribution queue I see the following status: RTY-FAIL Any idea's as to what may be causing this? Thanks, Mike mot98@yahoo.com wrote: > Hi All, > > We have two AS400's at different locations, and were able to > passthrough and send files between both no problems. > > Last week one of our AS400's was moved to another location, with an IP > change. > > We have updated the IP addresses on the other AS400 and can passthrough > fine....however we can no longer send files from the new location. > > When I look at the distribution queue I see the following status: > RTY-FAIL > > Any idea's as to what may be causing this? run the CFGDSTSRV command and then look at all the menu options. Another command to look at is CFGTCP. -Steve Steve Richter wrote: > mot98@yahoo.com wrote: > > Hi All, > > > > We have two AS400's at different locations, and were able to > > passthrough and send files between both no problems. > > > > Last week one of our AS400's was moved to another location, with an IP > > chan...

AS400 to AS400 data transfer
Hi I need to place a trigger on a set of tables on an AS400 to fire off whenever new records are added to these tables. This trigger program will then transfer the data to another AS400 across a WAN. This will allow us to transfer orders from one system to another. Can anyone tell me how I would achieve this. Normally if it had been a PC I would have used an ODBC type application but I am not sure what is available to me for AS400 to AS400 data transfer. I know that we can transfer a SAVF by FTP but this is not a route I would like to go down. I would prefer to populate tables directly if possible. Thanks for any help offered Iain Iain wrote: > Hi > > I need to place a trigger on a set of tables on an AS400 to fire off > whenever new records are added to these tables. This trigger program > will then transfer the data to another AS400 across a WAN. This will > allow us to transfer orders from one system to another. Even if there may be multiple way, I think the best would be using a remote journal, on the target system a journal entry exit program will be evoked at event time, so it can apply new records to the target tables, then it can fire a new event if necessary. -- Dr.Ugo Gagliardelli,Modena,ItalyCertifiedUindoscrasherA�ejoAlcoolInside Spaccamaroni andate a cagare/Spammers not welcome/Spammers v�o � merda Spamers iros a la mierda/Spamers allez vous faire foutre/Spammers loop schijten/Spammers macht Euch vom Acker/Spamerzy wypierdalac' ...

AS400 to AS400 data transfer #2
Hi I need to place a trigger on a set of tables on an AS400 to fire off whenever new records are added to these tables. This trigger program will then transfer the data to another AS400 across a WAN. This will allow us to transfer orders from one system to another. Can anyone tell me how I would achieve this. Normally if it had been a PC I would have used an ODBC type application but I am not sure what is available to me for AS400 to AS400 data transfer. I know that we can transfer a SAVF by FTP but this is not a route I would like to go down. I would prefer to populate tables directly if possible. We are using 2 model 820's with OS400 V5 R2 Thanks for any help offered Iain ...

IBM AS400
Does anyone have some notes, documentation or helful pointers about navigating, command language and DB2 on an AS400 for a guy who has done HP3000, Windows 2k/2k3, MS SQL, HP9000, IBM ES9000/UNIX, SCO UNIX? Ideally a commands cross reference qaulivalent would be terrific - I.E. HP3000 to AS400. Thanks much. P.S. I'm taking a role in a shop that runs its ERP system on this platform. Jim. ____________________________________________________________________________________ Get easy, one-click access to your favorites. Make Yahoo! your homepage. http://www.y...

CCSID problem on AS400 file download to PC
Hi I have a problem downloading a file from AS400 to PC where the file contains German language umlaut characters. The file is on an AS400 with a system language id of DEU German and a System CCSID of 65535. The file has been compiled with a CCSID of 273 - German. Within the file, the characters with umlauts have hex codes that match the expected values for code page 273. On a UK PC, I can use Client Access to download the file using the EBCDIC to ANSI conversion method and get a csv file with the correct German characters. I can also use the VB application that my colleagues are using to get the same results. My colleagues in Germany are using the Client Access express Active-X objects to download the file. The code specifies that EBCDIC to Ansi conversion is used on the download request. However, they lose the German characters. It appears from the characters that they see, that the EBCDIC to ASCII conversion used is treating the file as if it was coded as a UK file 037 and converting directly to ASCII from there. They can also use the Client Access download gui to manually get a correct copy of the file. Does anybody have any experience of using the Client Access download request active-x components in a multilanguage environment that can shed any light on what might be happening or where to go to get additional information ? Thanks, Mary > Does anybody have any experience of using the Client Access download request > active-x components in a multilanguage e...

Printing with AS400 in different subnets
Hi all, I'm not a AS400 specialist, but inherited a system with a company buyout. We have Linux servers and workstations, plus some windows workstations. The AS400 is now installed and working happily in our network. It also prints as it should on a printer (IBM NP17) in the same subnet (10.9.8.0/255.255.255.0). We have a VPN on Linux basis between two office buildings. The other subnet (10.9.7.0/255.255.255.0) where some users work in the stores also needs to print out from the AS400 to a printer (also an IBM NP17) in their subnet (office). Logged in with a client session in this other subnet that the AS400 is in (10.9.7.0/255.255.255.0), I can ping the printer from the AS400 with the command " ping '10.9.7.3' ". So the ping goes through the VPN and is returned by the printer to the AS400. When the AS400 prints, it moans that the printer is not switched on. I also added the printer name PRT02 to the host and routing table in the AS400. Why can I ping a printer but it won't print? When I use the same printer defined in the AS400 in its own subnet, it works. Just changing the same printer configuration to the other subnet does not work. We also copied the printer and queue definitions to another printer and queue PRT11 and just changed the IP addresses; to no avail. Why? All other windows systems can print on the printer. Are there some AS5400 peculiarities I should know of? Any ideas welcome. :-) LandSr Should be a plain routing issue. Ping is I...

PowerPC extensions for IBM AS400
Looking for an explanation or documentation on the as400 specific extensions to the PowerPC instruction set. Pointers on the as400 are stored as 16 byte values. The LQ ( load quad word ) and STQ ( store quad word ) instructions are used to load and store those pointers. Here is PPC assembler code that loads a pointer from an EA into a register: LQ 24, 0x1e50(30), 6 SELRI 26, 25, 0, 41 LQ loads the 16 bytes stored at EA reg30 + 0x1e50 into reg24 and reg25. The next SELRI stmt does something to reg25 and places the result in reg26. Does anyone know what the 3rd opera...

link table IBM AS400
Hi. Sorry for my english but I have MS Access in italian. My problem is by link a table from IBM As400 (with > 100.000 rows). The output of the table is many #ELIMINATO (in english "delete" / "erase".. I dont't know the exact message). I have tried with "requery" or recreating the link without results. If I *import* the table from AS400 it works perfectly without problems. Here an abstract txt BOLAZI;BOLCLI;BOLDBO;BOLNBO;BOLCAU;BOLNPR;BOLTRE;BOLMAT;BOLDES [........] [........] ;;;;;;;#Eliminato;#Eliminato ;;;;;;;#Eliminato;#Eliminato ;;;;;;;#Eliminato;#Eliminato 0;474;990204;354;10;1;1; 936;PC Intel Pentium II 400 Miditower 0;474;990204;354;10;4;1; 1890;CD-ROM drive 36X 0;474;990204;354;10;5;1; 1692;HD-SCSI 4.5 Gb IBM Ultrastar WIDE 7200 0;474;990204;354;10;6;1; 1497;HD-SCSI 9.1 Gb IBM DDRS-39130 UWIDE [........] Thanks in advance M. "Mire" <mary@hotmail.com> wrote in message news:buo9eo$k39dq$1@ID-57790.news.uni-berlin.de... > Hi. > Sorry for my english but I have MS Access in italian. > My problem is by link a table from IBM As400 (with > 100.000 rows). > > The output of the table is many #ELIMINATO (in english "delete" / "erase".. > I dont't know the exact message). > I have tried with "requery" or recreating the link without results. > > If I *import* the table from AS400 it works perfectly without problems. > &...

IBM AS400 certfication test papers
Aprax Consulting believes in developing professionals who believe in themselves and are equipped with the latest state of the art in their respective fields, professionals who are confident and can compete in the challenging world. The endeavor is to inculcate a desire for continuous improvement, a sense of healthy competition, and sensitivity towards ethical and moral values. Aprax consulting offers all types of certification test papers, dumps with 100% assurance of passing. 100% Money refunded if failed (except courier charges). All IBM certification including Mainframe certification, AS400 certification test papers available. IBM MAINFRAME DB2 certification IBM AS/400 RPGILE certification Contact: Aprax Consulting Ph(M): +91-9873500678 URL: www.apraxindia.com Email: hr@apraxindia.com Your 1st sentence is grammatically incorrect and doesn't make any sense. One question: Isn't your moral values endeavor compromised by selling dumps? ...

Sending MSGQ messages to another AS400
Does anyone know of a way to send a message from one AS400 message queue to a message queue on another AS400 You need to use SNDNETMSG. This requires that you set up a function called SNA/DS (SNA Distribution Services). As the name suggests it runs over SNA not TCP/IP. To use a TCP/IP network you will need to 'wra'p' the SNA traffic in TCP/IP, you do this usinh something called AnyNet. http://www-912.ibm.com/s_dir/slkbase.NSF/0/b56c1c34b489e7528625663d004b1797?OpenDocument&ExpandSection=1 http://www-912.ibm.com/s_dir/slkbase.nsf/1ac66549a21402188625680b0002037e/c0e073485d35f074862569da0063626f?OpenDocument&Highlight=0,anynet Note, you'll only have to configure Anynet if your network doesn't support SNA or the lan adapters in one or both of your iSeries doesn't support SNA -- Glenn <abat1999@yahoo.com> wrote in message news:1124850659.414901.140120@f14g2000cwb.googlegroups.com... > Does anyone know of a way to send a message from one AS400 message > queue to a message queue on another AS400 > ...

Copy Spool File to Another AS400
Is it possible to ftp a spool file to another AS400 so we can print it on one of its printers. if so how...thanks Pat Bradley V. Stone wrote: > If the printers are on your WAN, you should be able to create an IP > printer off each 400 so you can print from either 400 to the one > printer. (Other ways of doing this too, you weren't too specific > about your connections). > > You can also use SNDNETSPLF to send the spooled file to the other > machine. > > > On Fri, 01 Aug 2003 17:05:10 GMT, "kerleyp(you_must_remove_this)" > <"kerle...

Connecting to AS400 running on IBM with MS Access
Hello All, I've been struggling on and off for 3 months trying to connect to an DB2 database running on an IBM iSeries machine. I FINALLY figured out how to connect with Coldfusion (see instructions below). So, now I am trying to connect to the same database with MS Access. I want to link the tables within Access so I can quickly query and answer questions. The problem is that I HAVE NO IDEA how to do this. I'm familiar with linking tables to other databases (MySQL, MS SQL Server, Oracle), but I've never done it for IBM DB2 (I'm not even familiar with the IB...

ODBC drivers for IBM AS400 on Mac OsX
Hello, I need to know if there exists an ODBC driver (commercial too) for the IBM AS400 system (maybe DB2 is equivalent) that can be easily installed on a *Mac Os X*. I cannot usa jdbc because the program that needs to access this AS400 is FileMaker Pro 8, and it handles only odbc connections. Thank you for your help and patience, -- Guido | Experience is a strange teacher, | | it gives you the problem before the lesson | Sorry for the multiple posts, Guido > I need to know if there exists an ODBC driver (commercial too) > for the IBM AS400 system (maybe DB2 is equivalent) that can > be easily installed on a *Mac Os X*. > A quick google search didn't show much in the way of DB2 ODBC drivers for Mac, but there's an odbc-to-jdbc bridge product that may be helpful: http://uda.openlinksw.com/odbc/st/odbc-jdbc-bridge-st/ (click the Mac symbol at the bottom of the page) Kaj Julius wrote: > http://uda.openlinksw.com/odbc/st/odbc-jdbc-bridge-st/ > (click the Mac symbol at the bottom of the page) Thank you Kaj, I will take a look. -- Guido | Experience is a strange teacher, | | it gives you the problem before the lesson | ...

Does IBM AS400e Type 9406 work with Linux?
Does an IBM AS400e Type 9406 work with Linux? If so, which distribution is available? Al Al Bogner wrote: > Does an IBM AS400e Type 9406 work with Linux? If so, which > distribution is available? The following shows the which models support Linux. http://www-1.ibm.com/servers/eserver/iseries/linux/pdfs/guide.pdf ...

Way to tell if user is telneted from another AS400
Does anyone know how I can tell if a user telneted from another AS400 through a CL or RPG program. We now have 2 AS400s with division A, B & C on 1 and division D on the other. When a user needs to access D from A, B or C or vise versa they use a command to telnet them to the other AS400. Then they will us it to telnet back into the host. By the end of the day and single workstation might have 20 or 30 jobs running because they keep telneting instead of going back to the host. If anyone has any suggestions I would greatly apreciate it. Thanks Falco Hi Falco - On 10 Jun 2005 07:23:13 -0700, "Falco" <cwhitein@hotmail.com> wrote: >When a user needs to access D from A, B or C or vise versa they use a >command to telnet them to the other AS400. Then they will us it to >telnet back into the host. By the end of the day and single workstation >might have 20 or 30 jobs running because they keep telneting instead of >going back to the host. As long as the connections are not NATed, you could check the IP address of the device, see my webpage: http://www.ke9nr.net/iseries/faqs/devipaddr.shtml If the IP address is one of the AS/400s, take the appropriate action. Since you have just two systems, you could do a SIGNOFF with the option to drop the connection and that would take them back to where they were on the other system. (If you had more than two, it wouldn't be so simple.) WARNING: if some of the clients and AS/400s are on differ...

AS400 in windows domain integration with another windows domain
Currently we acquired a company that has AS400 with Kerberos auth/ iSeries navigator in a Windows domain. We built a one way trust to their domain that allows us to access their resources. One of those resources is the AS400 but we are having trouble integrating the iSeries navigator work with another domain. Any suggestions? Advise? Thank you in advance! On Aug 18, 5:36=A0pm, tc <tchang73...@yahoo.com> wrote: > Currently we acquired a company that has AS400 with Kerberos auth/ > iSeries navigator in a Windows domain. We built a one way trust to > their domain that allows us to access their resources. One of those > resources is the AS400 but we are having trouble integrating the > iSeries navigator work with another domain. Any suggestions? Advise? > Thank you in advance! Maybe a port issue, is there a way to bypass the kerberos at all to verify?? ...

Microsoft uses IBM AS400's for development.
Not well known but Microsoft uses IBM AS400 machines with the Windows server card option to develop programs. This option is really a PC on a card but offers significant advantages over a stand alone pc in that it can support virtual sessions of Windows each of which can be rebooted as required without bringing down the other seesions or worse the rest of the machine. Microsoft is a huge IBM AS400 customer. Most people assume developers are using PC's sitting next to their work space. Fadl Ullah Jonnalagadda wrote: > Not well known but Microsoft uses IBM AS400 machines with the Windows > server card option to develop programs. This option is really a PC on > a card but offers significant advantages over a stand alone pc in that > it can support virtual sessions of Windows each of which can be > rebooted as required without bringing down the other seesions or worse > the rest of the machine. Microsoft is a huge IBM AS400 customer. Most > people assume developers are using PC's sitting next to their work > space. MS developers are using Win 2k3 and Win 2k8 servers as development machines too and not PC(s), with VMware. Fadl Ullah Jonnalagadda wrote: Plonk "Fadl Ullah Jonnalagadda" <fadlullah.jonnalagadda@gmail.com> wrote in message news:60deb8d3-5599-48d8-8667-6734e37a756b@31g2000vbf.googlegroups.com... > Not well known but Microsoft uses IBM AS400 machines with the Windows > server card option to develop programs. ...

ibm as400 scsi drives in PC ? -newbie question-
i have aquired 5 ibm scsi drives and cages pulled from a retired AS400 server. i was hoping i could use them in a raid configuration connected to a generic PC with an adaptec 2940u2w . they are all recognized but throw up errors when writing to drive ( ie. formatting) are these compatable with regular PC scsi ? is it the drive microcode ? am i out of luck on these drives ? drive cage = type 6713 ibm FRU = 59H6611 drive model number = DGHS-09U date code 01APR99 (all 5 same date) The low leve format of the drives is different (520 vs. 512 for PCs as I recall) You should be able to find a utility to reformat them. HTH, Charles In article <3fr4h0hqcq8dpeibqkmac7cv9ilm85oupt@4ax.com>, reply@here.org says... > i have aquired 5 ibm scsi drives and cages pulled from a retired AS400 > server. > > i was hoping i could use them in a raid configuration connected to a > generic PC with an adaptec 2940u2w . > > they are all recognized but throw up errors when writing to drive > ( ie. formatting) > > are these compatable with regular PC scsi ? > > is it the drive microcode ? > > am i out of luck on these drives ? > > drive cage = type 6713 > ibm FRU = 59H6611 > drive model number = DGHS-09U date code 01APR99 (all 5 same date) > thank you , i`ll look into that - drives seem to stop responding after adaptec bios format utility is attempted - led activity indicator goes off - no writing noise ibm/hitachi ...

Using telnet client to connect to another as400 over internet
We have an as400 (with a private address) in out n/w , which is protected by a firewall(with a public address). There is another as400 in another n/w with the same config. We wanted to use client access or another telnet client, Symtrax to telnet to the other as400. After resolving all firewalling and connexion issues, we get the other as400 signon screen. If we use Client access, we note that the cursor positions itself one character before the user name input field. However it seems that whatever we type (which by the way would appear in small letters if the keyboard is in this mode) is not ...

SQL from AS400
I'm using ADO to pull a recordset from AS400. Everything works fine except my SQL. This SQL was generated using Microsoft query in Excel, and it works fine, obviously, when using MSQuery. It does not work when I put it in code. The rest of my code is fine, and has been tested successfully with a different, simpler SQL. Please advise. mySQL = "SELECT CUST.CCMPNY, CUST.CSPCL4, CUST.CCYCLE, CUST.CCUST#, CPRD.CPDESC, CPRD.CPCHG " & _ "FROM {oj ARWF.JGFTYT.CUST CUST LEFT OUTER JOIN ARWF.JGFTYT.CPRD CPRD ON CUST.CCUST# = CPRD.CPCST#} " & _ "WHERE (CPRD.CPCHG In ('CW','DF','MC','MK','CK','WE','LI','GA','GR','CO','BE','BS')) AND (SUBSTR(CSPCL4,1,2) In ('CW','DF'," & _ "'MC','MK','CK','WE','LI','GA','GR','CO','BE','BS')) AND (CUST.CCYCLE In ('RW','RR','RC','TR','WR','SB','SC','ZB','1','2','10'," & _ "'11','12','13','14','15','16')) AND (CUST.CCMPNY In ('1','3','4','5','6'))" & ";" -- RMC,CPA Richard wrote: > I'm using ADO to pull a recordset from AS400. Everything works fine except my SQL. This SQL was generated using Microsof...

AS400 job ?
I bring with me a hardcore development experience of above 10 years in the IT industry mainly on the IBM AS/400 computers. I have developed cost effective corporate ERP applications for the manufacturing/process, general banking and insurance industry. I have done major re-engineering projects and integrated applications across heterogeneous (OS) server platforms like Unix, Win NT/2000. I have used the latest development & project management tools and techniques in my projects. I have lead a large team of systems analyst, programmers and have given numerous presentations, conducted training sessions and interacted with people at all levels. Apart from the development work, I have actually set up large networks from scratch and installed servers. I have expertise in system administration of AS/400 machines and good command over Win NT/2000 servers installation, integration and administration. I am certified CLP5 (lotus notes) and CNA (netware). I am available immediately S. A. Pasha Email: sapasha2003@hotmail.com pashasa@rogers.com -- S. A. Pasha Email: sapasha2003@hotmail.com pashasa@rogers.com ...

AS400 TIM?
I have an AS400 tech info manual ... free to good home. Hi Greg...... CT or WBST? CT would like it......... CT (owner of an AS/400 terminal) On 25 Apr 2006 05:27:11 -0700, "Tim Knight/CT" <msgtknight@gmail.com> wrote: >Hi Greg...... > >CT or WBST? > >CT would like it......... > >CT (owner of an AS/400 terminal) T.I.M = Tech Info Manual but if that is also FOR "Tim" K that is fine with me. You still on Wal... Rd Savannah? gfretwell@aol.com wrote: > On 25 Apr 2006 05:27:11 -0700, "Tim Knight/CT" <msgtknight@gmail.com> > wrote: > > >Hi Greg...... > > > >CT or WBST? > > > >CT would like it......... > > > >CT (owner of an AS/400 terminal) > > > T.I.M = Tech Info Manual but if that is also FOR "Tim" K that is fine > with me. You still on Wal... Rd Savannah? I sure am.....gonna be here until I go into cyberspace myself. Please allow me to pay the postage at least, OK? CT On 25 Apr 2006 08:51:09 -0700, "Tim Knight/CT" <msgtknight@gmail.com> wrote: > >gfretwell@aol.com wrote: >> On 25 Apr 2006 05:27:11 -0700, "Tim Knight/CT" <msgtknight@gmail.com> >> wrote: >> >> >Hi Greg...... >> > >> >CT or WBST? >> > >> >CT would like it......... >> > >> >CT (owner of an ...

Web resources about - From a AS400 with a CCSID to another AS400 with different CCSID - comp.sys.ibm.as400.misc

ISIS Links Brussels Attack and Paris Massacre, Say Reports
Brussels airport attack has close links to the terror cell that carried out the November Paris attack. With investigative agencies working on ...

Apple Promotes Microsoft Office 365 as iPad Pro 'Accessory'
Following the unveiling of the 9.7-inch iPad Pro at Apple's media event on Monday, Apple CEO Tim Cook described the device as the "ultimate PC ...

North Carolina reins in local governments, transgender rule
RALEIGH, N.C. (AP) — North Carolina legislators decided to rein in local governments by approving a bill that prevents cities and counties from ...

Google Maps iOS app now gives ride fares & pickup times for five more services
The iOS Google Maps app has long shown you Uber fares and pickup times when you search for a destination, provided that you have the Uber app ...

Man kisses police officer during confrontation, fight breaks out
When a police officer in Liuzhou City, China, found himself in a heated argument with a street vendor resisting arrest, the last thing he expected ...

Aussie comedy 'The Justice Lease' brings Batman v Superman to the suburbs
A new Aussie YouTube comedy series asks who would really win in a fight if Superman and Batman lived in a sharehouse in the suburbs. Welcome ...

SteamVR recreates your PC desktop in virtual reality
Steam already offered (compatible) VR headset owners the ability to drag their (ugh!) two-dimensional games, kicking and screaming, into virtual ...

‘The Force Awakens:’ Torrent Sites Leak Pirated ‘Star Wars Episode VII’ Blu-ray Rip
Though the Blu-ray Star Wars release date is not scheduled until April 5, as reported by Amazon, a The Force Awakens torrent was uploaded to ...

Justices Seem Split in Case on Birth Control Mandate
WASHINGTON — The Supreme Court weighed moral theology and parsed insurance terminology on Wednesday in an extended and animated argument that ...

Australia says Mozambique debris likely from missing MH370
By Byron Kaye and Swati Pandey SYDNEY (Reuters) - Australia said on Thursday debris recovered this month in Mozambique was highly likely to be ...

Resources last updated: 3/24/2016 11:57:08 AM